PLMNL0252 REV. B Effective Date: 10/16/17
17
FiberCUT
®
HR Operation Manual
There are 4 digital inputs (Cal,
Reset, Move and Enable)
available through the terminal
block connection.
DIGITAL INPUTS
INPUT
DESCRIPTION
Cal In
The Cal In input recalibrates the
height sensor.
Clear any HSU faults by activating
this input for 20
– 200 µsec.
Reset In
The Reset In input clears any
position faults and moves the focus
to the Home position.
Move In
When the Move input is active, the
focus position will follow the Pos In
analog input.
Enable In
The Enable input will activate the
servo in order to adjust the focus
position.
3.5.2 Industrial Ethernet Connection
The Industrial Ethernet (IE) interface
provides extensive control and
monitoring of the FiberCUT
®
HR.
Depending on the control box model,
either EtherNet/IP or PROFINET
communications protocol is used.
configuration and available data.
3.6 Control Box Indicator Lights
The control box has 7 indicator lights. See
The indicator light labeled
POWER
is
green and illuminated when power is
supplied to the control box.
The indicator light labeled
READY
is
illuminated in green when the
READY
output is active. The light illuminates
in red when a fault is detected within
the head.
The indicator light labeled
TOUCH
is
green and illuminated when the tip is
in contact with the part or another
conductive surface.
The indicator lights labeled
A
,
B
,
C
,
and
D
may be red or green. They
work together to indicate the network
status of the IE connection and other
diagnostic information. See the charts
below.
At power up or reset, the four
indicators will cycle in the order
A
>
B
>
D
>
C
first in red and then in
green. This pattern confirms the IE
module is installed and functioning
properly.
Figure 24
During normal operation the indicator lights respond
as follows:
LED A
STATE
STATUS
Green
Module connected to a network
Green and
Flashing
RX / TX Activity