PLMNL0252 REV. B Effective Date: 10/16/17
21
FiberCUT
®
HR Operation Manual
1. Click the following, as necessary:
Under proper operating
conditions, click the
Servo
Enable
button to command
the servo to turn on and
maintain the set position.
o
Click the button while the
servo is active to disable.
ENABLE IN
must be active on the
Control Box before you can set
Servo Enable
.
Click the
Reset
button to allow
the servo to be enabled and
clear a
Position Fault
.
To modify the
Set Position
o
Use the slider bar on the
right to update the
Set
Position
value.
o
Click the
Go
button to
apply the new value.
Click the
Calibrate
button to
recalibrate the HSU.
Perform calibration at 12 mm
above the material surface.
o
Use the
Calibrate
button
to clear a
Tip
or
Cable
Break
fault.
o
An alternate method to
recalibrate the FiberCUT
®
Monitor is to click the
Settings menu in the
upper left corner of the
Main screen and select
Calibrate. See
Figure 30
Click the
Disconnect
button
(top center of the Main
Screen) or the red X (upper
right corner of the Main
screen) to disconnect the
control box and head.
o
Either of these actions will
end the session.
2. Note the following displays:
The status of the head is
displayed in the upper right
corner of the Main Screen.
If the tip contacts another
surface, the indicator light
next to TIP TOUCH (lower
right of the Main screen) will
be illuminated green.
The Main screen displays the
current value of:
o
Standoff Height
o
Focus Position
o
Temperature for
electronics, both cover
glasses, process monitor,
and both parabolas
o
Purge gas pressure