PLMNL0252 REV. B Effective Date: 10/16/17
22
FiberCUT
®
HR Operation Manual
4.3.3 Faults and Status Indicator
When a fault occurs, the
Ready
output
turns off and the corresponding light
on the control box turns red. A
description of the fault is also
displayed in red in the upper right
corner of the Main screen and the
module responsible for the fault will be
highlighted on the diagram of the
head.
Faults occur when:
The HSU fails to calibrate.
A cable break occurs within the
head. For instance, if the tip
assembly is removed or one of the
external modules is not
connected.
Communication between the
controller and head is lost.
A temperature or voltage goes
above the upper limit.
The cover glass door is open or
drawer is removed.
The purge pressure goes below
the lower limit (unless
suppressed) or above the upper
limit.
The nozzle assembly moves
unexpectedly or encounters
difficulty moving to the
commanded position.
The status indicator may also show
that the head is Not Ready if the head
is operating normally but is not ready
for laser processing, such as when the
HSU is calibrating.
The on-screen Ready indicator may
not change during some operations
due to the software refresh interval.
See the READY output or light on the
control box for real-time status.
4.4 FiberCUT
®
Monitor Settings
The FiberCUT
®
Monitor software and
driver are available for download.
See
This section lists the settings that
must be specified before operating
FiberCUT
®
Monitor.
Before adjusting any settings:
The software must be installed on your
PC. See
The head and control box must be
connected properly. See
more details.
4.4.1 Unlock Settings
1. Click the
Settings
menu in the
upper left corner of the Main
screen and select
Unlock
Settings
. See
In the pop up that appears,
enter the password:
cutsetup
Figure 31