PLMNL0252 REV. B Effective Date: 10/16/17
45
FiberCUT
®
HR Operation Manual
13 Appendix F
– Industrial Ethernet Data Mapping and Descriptions
13.1 EtherNet I/P I/O Mapping
The EDS file is available for download at
http://www.lasermech.com/fibercut2dupdates
WORD
TYPE
NAME
0
Input Data
Digital Outputs
1
Input Data
HSU Voltage
2
Input Data
Process Monitor
3
Input Data
Purge Pressure
4
Input Data
Current Position
5
Input Data
Process Monitor Temp
6
Input Data
HSU Temp
7
Input Data
Upper CG Temp
8
Input Data
Collimating Parabola Temp
9
Input Data
Focusing Parabola Temp
10
Input Data
Lower CG Temp
11
Input Data
Scattered Light
12
Input Data
HSU Curve
13
Input Data
Reserved For Future Use
14
Input Data
Focus Position
15
Input Data
Maximum Position
16
Input Data
Process Monitor Gain
0
Output Data
Digital Inputs
1
Output Data
Set Target Position
2
Output Data
Set HSU Curve
3
Output Data
Set Focus Position
4
Output Data
Reserved For Future Use
5
Output Data
Set Process Monitor Gain
Digital Outputs
BIT 15
BIT 14
BIT 13
BIT 12
BIT 11
BIT 10
BIT 9
BIT 8
No Comm.
Optics Fault
Temperature
Fault
Purge
Fault
Position
Fault
HSU Fault
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved For
Future Use
Move Input
Active
Cal Ack.
Servo
Enabled
In Position
Servo Is
On
TOUCH
READY
Digital Inputs
BIT 15
BIT 14
BIT 13
BIT 12
BIT 11
BIT 10
BIT 9
BIT 8
Reserved For Future Use
Enable
Servo
Suppress Low
Purge Fault
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved For Future Use
Zero
Pressure
Move
Nozzle
Reset
CAL
ITEM
DESCRIPTION
Device Anybus-IC EIP
Name
Exclusive Owner
Input
17 INT, Connection Point 100
Output 6 INT, Connection Point 150