17
charger lights;
- charge time of the discharged battery is 14...14.5 h;
- disconnect the charger from the rangefinder.
5) after long-duration interval in operation with the rangefinder (more than one
month) it is necessary to carry out training of the energy storage capacitor of
the head supply unit.
Carry out training in the following manner:
a) shift the supply tumbler of the rangefinder to the
ON
position;
b) after 10...15 s press and release the start button;
c) repeat the operations according to the clause b) until the green readiness
indicator on the digital indicator display lights (see Fig.5), after that the
rangefinder is ready to measure.