REGOLATION AND POSITION OF ULTRASONIC SENSOR
Fix the two capsules on the side at the top of front windshield, and orient towards the rear
window, keeping horizontal and parallel to each other. Connect the red (Tx) connector
coming from the capsule to the red connector of control unit and make the same with the
White connectors (Rx)
TRIMMER OF ULTRASONIC SENSOR
The ultrasonic sensitivity adjustment must be made initially setting it low, then increasing it
gradually until you get adequate coverage even in the back of the car;
not further increase the sensitivity to avoid the risk of false alarms.
Note: The minimum sensitivity is obtained with the fully counterclockwise
adjustment, and the maximum clockwise.
In case you want to verify the ultrasonic sensor activity proceed as follows:With alarm
being disarmed, bring the front window down for 20cm.
Adjust the trimmer located on the ultrasonic module.
Arming the system and wait for total arm ng (LED flashing) with doors, connect the
i
presence detection.
If the alarm does not trigger, adjust the ultrasonic trimmer clockwise and repeat the test.
If the alarm does trigger without introducing an object adjust the trimmer anti clockwise.
SENSITIVITY ADJUSTMENT
Clockwise:maximum sensitivity
Anti clockwise: minimum sensitivity
Anti clockwise until the end: sensor
exluded
ELETRICAL CONNECTIONS
FIXING AND PLACEMENT