background image

 
 

COMPONENTS 

 
 
 
4001-0000

    

Quad 1000

  5 arc second zenith laser 

featuring electronic servo self-leveling with variable 
temperature compensation for the most accurate and 
consistent readings. Features downward shooting laser 
plumb-bob for getting over your point, upward zenith 
laser to 1,200 feet (366m), one button operation with 
LCD display and up to 140 hrs. battery life. 

 
 
 

 

4200-0000

    

Trivet Floor Mount

 with a 5/8 x 11 thread 

mount and adjustable legs. Made of heavy duty aluminum 
with a finished textured black E-coating surface and a handle 
on each side for easy, safe positioning. 

 

 
 

4001-0010

    

Target Template

 (2ea.) with “ultra-bright”  bulls-eye for 

the most visible and precise readings at any distance. Targets feature 
laser pass through allowing multiple readings at one time, special hard 
coating that protects the graphics on the target face and two ¼ inch 
holes for custom mounting. 

 
 
 

 

4000-0200

    

Carrying Case

 double wall blow molded, 

custom fit foam inserts and two locking latches for securing 
your items. 

 
 
 
 
 

 

4001-XXXX

     

Owner’s Manual - Operators Guide

 

 

 

 

 

Summary of Contents for QUAD 1000

Page 1: ...QUAD 1000 OWNERS MANUAL OPERATION GUIDE Built in Redmond Oregon USA www laserlinemfg com...

Page 2: ...mount and adjustable legs Made of heavy duty aluminum with a finished textured black E coating surface and a handle on each side for easy safe positioning 4001 0010 Target Template 2ea with ultra bri...

Page 3: ...ling status and battery power are displayed on the LCD screen The downward shooting smaller beam plumb bob is activated and will be blinking Once the Quad has self leveled to within its operating spec...

Page 4: ...has leveled E Once leveled slide the trivet until the plumb laser is directly over your point The instrument is now projecting a beam reference at Zenith USING A TRIPOD Standard flat head with 5 8x 11...

Page 5: ...base and one line is centered on the notch on the front of the Quad The instrument is now directly over the reference point C Power up the Quad 1000 ALIGNMENT TEMPLATE TARGETS A They can be used as a...

Page 6: ...d calibration check have it checked by your Dealer Service Department MAINTENANCE The Quad 1000 requires no maintenance other than periodically cleaning the laser output lens Use a soft cloth with Win...

Page 7: ...7mm Nominal 300 91m 375 9 52mm 500 152m 500 12 7mm 700 213m 687 17 46mm 900 274m 875 22 22mm 1 200 366m 1 15 29 3mm Environment Operating Temperature 0 to 122F 18 to 50c Storage Temperature 4 to 158...

Page 8: ...e enclosed instructions in this manual Warning Under no circumstances attempt to open or disassemble the Laser Housing Doing so may cause exposure to potentially hazardous levels of laser radiation Ca...

Reviews: