background image

 

JOBSITE CALIBRATION CHECK 

 

1.

 

Using the trivet mount, tripod or deck / slab mount as shown in 

“Setting Up” 

get 

the Quad 1000 precisely over your reference point on the ground floor.

 

 

2.

 

Place the target / template precisely centered on the laser spot at the highest 
point possible above the Quad 1000. (At least 100 feet if possible) Secure the 
target so it will not move.

 

 

3.

 

Rotate the Quad 1000 180° and very precisely set it over the reference point. 

 

 

4.

 

Go back to the target and measure any change of the laser spot relative to the 
bulls-eye target.

 

 

 Given the dynamics and movement of structures due to temperature, wind, loads 
etc., the target relation to the Quad 1000 laser may be moving and not providing a 
constant. This should definitely be taken into consideration so as a result, depending 
on conditions, you could be getting readings of 

 1/16 or 

 1/8 at the target per 100 

vertical feet. If you are not comfortable or confident with the field calibration check, 
have it checked by your Dealer Service Department. 
 

 
MAINTENANCE

 

The Quad 1000 requires no maintenance other than periodically cleaning the laser 
output lens. Use a soft cloth with Windex or alcohol. 

*NOTE: Laser must be turned OFF when cleaning the lens! 

 

CERTIFICATION 

This laser product in the USA classifies as a Class IIIa under CDRH 21CFR 1040.10  
and 1040.11 
This product classifies internationally as a Class 3R under IEC 60825-1 2014 
 

LASER SAFETY 

The maximum power output of this laser is less than 5mw. A laser safety kit is supplied 
with the Quad 1000 laser. The kit contains operator qualification cards and a sign that 
should be posted near the laser whenever it is in use. Observe the following rules: 

 

Never look directly into a laser beam or point the beam into the eyes of others. 
Set the laser at a height that prevents the beam from shining directly into 
people’s eyes. 

 

DO NOT remove any warning signs from the laser. 

 

Only properly trained people are to use this product. 

 

If service is required, which results in the removal of the outer protective cover, 
only factory-trained personnel must perform this. 

 

Summary of Contents for QUAD 1000

Page 1: ...QUAD 1000 OWNERS MANUAL OPERATION GUIDE Built in Redmond Oregon USA www laserlinemfg com...

Page 2: ...mount and adjustable legs Made of heavy duty aluminum with a finished textured black E coating surface and a handle on each side for easy safe positioning 4001 0010 Target Template 2ea with ultra bri...

Page 3: ...ling status and battery power are displayed on the LCD screen The downward shooting smaller beam plumb bob is activated and will be blinking Once the Quad has self leveled to within its operating spec...

Page 4: ...has leveled E Once leveled slide the trivet until the plumb laser is directly over your point The instrument is now projecting a beam reference at Zenith USING A TRIPOD Standard flat head with 5 8x 11...

Page 5: ...base and one line is centered on the notch on the front of the Quad The instrument is now directly over the reference point C Power up the Quad 1000 ALIGNMENT TEMPLATE TARGETS A They can be used as a...

Page 6: ...d calibration check have it checked by your Dealer Service Department MAINTENANCE The Quad 1000 requires no maintenance other than periodically cleaning the laser output lens Use a soft cloth with Win...

Page 7: ...7mm Nominal 300 91m 375 9 52mm 500 152m 500 12 7mm 700 213m 687 17 46mm 900 274m 875 22 22mm 1 200 366m 1 15 29 3mm Environment Operating Temperature 0 to 122F 18 to 50c Storage Temperature 4 to 158...

Page 8: ...e enclosed instructions in this manual Warning Under no circumstances attempt to open or disassemble the Laser Housing Doing so may cause exposure to potentially hazardous levels of laser radiation Ca...

Reviews: