JOBSITE CALIBRATION CHECK
1.
Using the trivet mount, tripod or deck / slab mount as shown in
“Setting Up”
get
the Quad 1000 precisely over your reference point on the ground floor.
2.
Place the target / template precisely centered on the laser spot at the highest
point possible above the Quad 1000. (At least 100 feet if possible) Secure the
target so it will not move.
3.
Rotate the Quad 1000 180° and very precisely set it over the reference point.
4.
Go back to the target and measure any change of the laser spot relative to the
bulls-eye target.
Given the dynamics and movement of structures due to temperature, wind, loads
etc., the target relation to the Quad 1000 laser may be moving and not providing a
constant. This should definitely be taken into consideration so as a result, depending
on conditions, you could be getting readings of
1/16 or
1/8 at the target per 100
vertical feet. If you are not comfortable or confident with the field calibration check,
have it checked by your Dealer Service Department.
MAINTENANCE
The Quad 1000 requires no maintenance other than periodically cleaning the laser
output lens. Use a soft cloth with Windex or alcohol.
*NOTE: Laser must be turned OFF when cleaning the lens!
CERTIFICATION
This laser product in the USA classifies as a Class IIIa under CDRH 21CFR 1040.10
and 1040.11
This product classifies internationally as a Class 3R under IEC 60825-1 2014
LASER SAFETY
The maximum power output of this laser is less than 5mw. A laser safety kit is supplied
with the Quad 1000 laser. The kit contains operator qualification cards and a sign that
should be posted near the laser whenever it is in use. Observe the following rules:
Never look directly into a laser beam or point the beam into the eyes of others.
Set the laser at a height that prevents the beam from shining directly into
people’s eyes.
DO NOT remove any warning signs from the laser.
Only properly trained people are to use this product.
If service is required, which results in the removal of the outer protective cover,
only factory-trained personnel must perform this.