background image

06

Inserting battery

Open the battery compartment and insert 

battery according to the symbols. 

Be sure to pay attention to polarity.

Danger - powerful magnetic fields

–  Powerful magnetic fields can adversely affect persons with active 

medical implants (e.g. pacemaker) as well as electromechanical 

devices (e.g. magnetic cards, mechanical clocks, precision mechanics, 

hard disks).

–  With regard to the effect of powerful magnetic fields on persons, 

the applicable national stipulations and regulations must be  

complied with such as BGV B11 §14 „electromagnetic fields“ 

 

(occupational health and safety - electromagnetic fields) 

 

in the Federal Republic of Germany.

–  To avoid interference/disruption, always keep the implant or device 

a safe distance of at least 30 cm away from the magnet.

Safety instructions

Dealing with electromagnetic radiation
–  The measuring device complies with electromagnetic compatibility  

regulations and limit values in accordance with EMC-Directive 

2014/30/EU.

–  Local operating restrictions – for example, in hospitals, aircraft,  

petrol stations or in the vicinity of people with pacemakers –  

may apply. Electronic devices can potentially cause hazards  

or interference or be subject to hazards or interference.

General safety instructions

–  The device must only be used in accordance with its intended  

purpose and within the scope of the specifications.

–  The structure of the device must not be modified in any way.

–  Do not expose the device to mechanical stress, extreme  

temperatures or significant vibration

Function / Application

This digital hygrometer provides information on the ambient  

temperature and relative humidity. The device saves the minimum  

and maximum climate values. The user is warned of high air humidity 

and dryness. The room climate can be improved using the ventilation 

recommendation. A well-balanced room climate has a positive  

influence on health and comfort levels. Climate data and the time 

 

are clearly displayed. The fold-out stand/clip and integral magnets 

allow the device to be placed on tables, attached to objects,  

or fixed to metal surfaces. 

Completely read through the operating instructions, the 

„Warranty and Additional Information“ booklet as well as 

 

the latest information under the internet link at the end  

of these instructions. Follow the instructions they contain.  

This document must be kept in a safe place and passed on 

together with the device.

!

EN

Summary of Contents for ClimaHome-Check Plus

Page 1: ...ClimaHome Check Plus 02 06 10 14 18 22 26 30 34 38 42 46 50 54 58 62 66 70 74 78 82 86 90 94 DE EN NL DA FR ES IT PL FI PT SV NO TR RU UK CS ET RO BG EL SL HU SK HR 9 9 C 50 C 1 99 rH magnetic...

Page 2: ...en z B in Krankenh usern in Flugzeugen an Tankstellen oder in der N he von Personen mit Herzschrittmachern sind zu beachten Die M glichkeit einer gef hrlichen Beeinflussung oder St rung von und durch...

Page 3: ...LC Display LED Luftfeuchtewarnung Timer einstellen MIN MAX Werte umschalten Ausklappbarer St nder Wandhalterung Batteriefach 1 2 3 4 5 6 7 Das Ger t ist f r den Einsatz an festen Messorten optimiert B...

Page 4: ...DE 04 5 Uhrzeit einstellen 3 Timer einstellen 4 Timer l schen 2 sec 1x 1 1 1x 1 sec 10 1x 1 sec 1x 2 sec 1x 1x 1x 2x 6 Luftfeuchtewarnung einstellen 2x 2 sec 1x 1x...

Page 5: ...rennt gesammelt und entsorgt werden Weitere Sicherheits und Zusatzhinweise unter http laserliner com info an AKO Technische Daten Technische nderungen vorbehalten 21W33 Luftfeuchte Messbereich relativ...

Page 6: ...s may apply Electronic devices can potentially cause hazards or interference or be subject to hazards or interference General safety instructions The device must only be used in accordance with its in...

Page 7: ...MAX values display Relative humidity in rH Ambient temperature in C a b c d LC display LED Humidity warning Set timer Switch MIN MAX values Fold out stand Wall bracket Battery compartment 1 2 3 4 5 6...

Page 8: ...08 2 sec 1x 1 1 1x 1 sec 10 1x 1 sec 1x 2 sec 1x 1x 1x 2x 2x 2 sec 1x 1x 6 Set humidity warning 4 Cancel timer 3 Set timer 5 Set time EN...

Page 9: ...th and do not use cleaning agents scouring agents and solvents Store the device in a clean and dry place Technical data Subject to technical changes without notice 21W33 Humidity Measuring range relat...

Page 10: ...Co KG Donnerfeld 2 59757 Arnsberg Germany Tel 49 2932 638 300 Fax 333 www laserliner com Rev21W33 SERVICE Umarex GmbH Co KG Laserliner M hnestra e 149 59755 Arnsberg Germany Tel 49 2932 638 300 Fax 49...

Reviews: