DigiLevel Plus
07
2
3
1
4
Switching on and measuring
The DigiLevel Plus can measure angles continuously
to 360°.
– Switch the DigiLevel Plus on using the on/off switch (4).
– The slope angle is shown in the display (8). If slopes
are measured overhead, the direction of display
adjusts automatically.
– The current slope direction is also shown by
the symbol (7).
Selection of unit of measurement
Button (5) allows the desired unit of measurement to be
selected (° degrees, %, mm/m).
Inserting batteries
Open the battery com-
partment and insert
batteries according
to the symbols. Be
sure to pay attention
to polarity.
Calibration
1. Place the measuring face (17) on an even surface with
position mark (see Fig. below). Switch on device (4) and
keep the CAL button (3) pressed until CAL 1 appears
on the display.
2. Press the CAL button (3) again. CAL 1 flashes. The
display then switches to CAL 2 and a signal sounds.
3. Now turn the spirit level vertically by 180° and
place exactly on the marked surface (reverse
measurement).
4. Press the CAL button (3) again until CAL 2 flashes.
The subsequent acoustic signal concludes the process.
The unit is properly calibrated when it displays
the same measurement value, i.e. the underlying
surface‘s deviation from absolute level, in both
positions (0° and 180°).
!
Make sure that the reference function
is deactivated before measuring.
!