background image

02

Laser

2 x Typ AAA / LR03 
1,5V / Alkaline

A

Summary of Contents for DistanceMaster Compact Plus

Page 1: ...DistanceMaster Compact Plus Laser 650 nm SPEED SHUTTER 04 DE 10 EN 16 NL 22 DA 28 FR 34 ES 40 IT 46 PL 52 FI 58 PT 64 SV 70 NO TR RU UK CS ET RO BG EL SL HU SK HR 76...

Page 2: ...02 Laser 2 x Typ AAA LR03 1 5V Alkaline A...

Page 3: ...DistanceMaster Compact Plus 03 x y m2 x y x y z x y z m3...

Page 4: ...Achtung Nicht in den direkten oder reflektierten Strahl blicken Den Laserstrahl nicht auf Personen richten Falls Laserstrahlung der Klasse 2 ins Auge trifft sind die Augen bewusst zu schlie en und der...

Page 5: ...zeige L nge Fl che Volumen Digital Connection Funktion aktiviert Batteriesymbol Zwischenwerte min max Werte Messwerte Messergebnisse Einheit m ft inch _ _ min max Dauermessung 1 2 4 3 Einsetzen der Ba...

Page 6: ...Messung Laser an 2 Messung 1x 1 sec 2x 3x L ngenmessung Ger t an Laser an Messung 3 sec 1x 3 sec 1x 1 sec 2x 3x 1x 1x 1 sec Einschalten Messen und Ausschalten Ger t an Laser an Messen Ger t aus L sch...

Page 7: ...tion finden Sie unter http laserliner com info an ble Das Ger t kann eine Funkverbindung mit Funkstandard IEEE 802 15 4 kompatiblen Ger ten aufbauen Der Funkstandard IEEE 802 15 4 ist ein bertragungsp...

Page 8: ...geschr nkt einsetzbar und kann bei starker Sonneneinstrahlung nicht verwendet werden Bei Messungen im Freien k nnen Regen Nebel und Schnee die Messergebnisse beeinflussen bzw verf lschen Bei ung nstig...

Page 9: ...nd Elektronik Altger te getrennt gesammelt und entsorgt werden Weitere Sicherheits und Zusatzhinweise unter http laserliner com info an ACG bis 10 m Messabstand bei gut reflektierender Zieloberfl che...

Page 10: ...e device must only be used in accordance with its intendedpurpose and within the scope of the specifications The measuring tools and accessories are not toys Keep out of reach of children Modification...

Page 11: ...lowing address http laserliner com info an ACG The measuring accuracy may be affected when working close to high voltages or high electromagnetic alternating fields EN DISPLAY a b c d e f g h i j k Me...

Page 12: ...last measured value Change unit of measure m ft inch _ _ Change measurement point reference rear device on front 1x 2x 1x 1 sec 1x 1 sec 2x 3x 1x 2x 4x 3x Change measurement function length area volu...

Page 13: ...to a maximum distance of 10 m from the terminal device and greatly depends on the ambient conditions such as the thickness and composition of walls sources of interference as well as the transmit rece...

Page 14: ...ces Error codes Err101 Err104 Err152 Err153 Err154 Err155 Err156 Err157 Err160 Replace the battery Calculation error Temperature is too high 40 C Temperature is too low 0 C Outside the measuring range...

Page 15: ...e collected separately for disposal according to the European Directive on waste electrical and electronic equipment Further safety and supplementary notices at http laserliner com info an ACG measuri...

Page 16: ...serliner M hnestra e 149 59755 Arnsberg Germany Tel 49 2932 638 300 Fax 49 2932 638 333 info laserliner com Umarex GmbH Co KG Donnerfeld 2 59757 Arnsberg Germany Tel 49 2932 638 300 Fax 333 www laserl...