DigiLevel Laser G40/G80
11
2
3
1. Place the unit with its measuring edge (18) down on a straight
surface and mark the positions of the unit‘s ends on the
underlying surface (see Fig. below). Switch the unit on (4) and
press the CAL button (3) until CAL 1 will appear in the display.
2. Press the CAL button (3) again. CAL 1 flashes. The display then
changes to CAL 2.
3. Now turn the unit around horizontally (end-for-end) by 180°
such that its ends are positioned opposite where they previously
were but again exactly at the underlying surface marks (reverse
measurement). Again press the CAL button (3). CAL 2 flashes.
Calibration is concluded when the measured value appears on
the display.
The unit is properly calibrated when it displays the same
measurement value, i.e. the underlying surface‘s deviation
from absolute level, in both positions (0° and 180°).
!
Calibration
4
Button (5) allows the desired unit of measurement to be selected
(° degrees, %, mm/m).
Selection of unit of measurement
The DigiLevel Laser G40 / G80 can measure angles continuously to 360°.
– Switch the DigiLevel Plus on using the on/off switch (4).
– The slope angle is shown in the display (8). If slopes are measured
overhead, the direction of display adjusts automatically.
– The current slope direction is also shown by the symbol (7).
Make sure that the reference function is deactivated before
measuring.
!
Switching on and measuring
EN
DigiLevel Laser
With button (2), it is possible to transfer angles elsewhere. To do
so, set the device to the desired slope and press button (2). The
display then changes to „0.0°“, „REF“ flashes on the display and the
required reference angle is set. The slope can now be transferred to
other objects.
5
Changing the angle reference value