10
EN
Err204:
Err208:
Err220:
Err252:
Err253:
Important notices
– The laser points to the location that will be measured.
No objects may get into the laser‘s line of measurement.
– The device compensates the measurement for different room
temperatures. Therefore allow the device a brief adaptation period
when changing locations with large temperature differences.
– The device is only conditionally useable in outdoor areas and cannot
be used in strong sunlight.
– The measurement results of outdoor measurements may be influenced
or falsified by rain, fog and snow.
– In unfavourable conditions, e.g. with poorly reflecting surfaces,
the maximum deviation may be greater than 3 mm.
– Carpeting, upholstery or curtains will not reflect the laser optimally.
Measure to flat surfaces.
– Measurements made through glass (window panes) can falsify
measurement results.
– An energy-saving function switches the device off automatically.
– Clean with a soft cloth. Water may not be allowed to penetrate
the housing.
Error codes:
Calculation error
Internal fault
Replace the battery
Temperature is too high: > 40°C
Temperature is too low: < 0°C
1x
1x
2 sec
Length measurement:
device on
measure / hold
After switching on, the device starts with continuous
measurement.
!
3x
2x
1x
1x
2 sec
Change unit of measure:
device on (m)
_‘ _“
inch
ft
+
Summary of Contents for LaserRange-Master T2