background image

LaserRange-Master T2

11

EN

* measuring distance up to 10 m with strongly reflective target surface 
and at room temperature. The measurement deviation may increase by  
± 0.2 mm/m for greater distances and under unfavourable measuring 
conditions such as strong sunlight or weakly reflective target surfaces.

EU directives and disposal

This device complies with all necessary standards  
for the free movement of goods within the EU.
This product is an electric device and must be  
collected separately for disposal according to  
the European Directive on waste electrical and  
electronic equipment.
Further safety and supplementary notices at:  

http://laserliner.com/info?an=ACX

Err255:
Err256:
Err261:
Err500:

Received signal too weak or measuring time too long
Received signal too strong
Outside the measuring range
Hardware fault

Technical Data

 

(Subject to technical changes without notice. 19W47)

Precision (typical)*

± 2 mm

Measurement range (inside) ** 0.2 m - 20 m
Laser class

2 / < 1 mW (EN 60825-1:2014/AC:2017)

Laser wavelength

650 nm

Beam divergence

< 1.5 mrad

Operating conditions

0°C … 40°C, max. humidity 20 …  
85% rH, no condensation, max. work-
ing altitude 2000 m above sea level

Storage conditions

-20°C … 70°C, max. humidity 80% rH

Automatic switch-off

Dynamic depending on measuring 
mode:
Laser: 30 s … 5 min
Device: 3 min … 8 min

Power supply

2 x 1.5V LR03 (AAA)

Dimensions (W x H x D)

35 x 100 x 23 mm

Weight

82 g (incl. batteries)

Information on maintenance and care

Clean all components with a damp cloth and do not use cleaning agents, 
scouring agents and solvents. Remove the battery(ies) before storing for 
longer periods. Store the device in a clean and dry place.

Calibration

The measuring device should be calibrated and tested on a regular 
basis to ensure it is accurate and working properly. We recommend 
the measuring device is calibrated every 1 - 2 years. If necessary, contact 
your distributor or the UMAREX-LASERLINER service department.

** at max. 5000 lux

Summary of Contents for LaserRange-Master T2

Page 1: ...LaserRange Master T2 Laser 650 nm SPEED SHUTTER 04 08 12 16 20 24 28 32 36 40 44 48 DE EN NL DA FR ES IT PL FI PT SV NO TR RU UK CS ET RO BG EL SL HU SK HR...

Page 2: ...02 Laser...

Page 3: ...LaserRange Master T2 03 1 4...

Page 4: ...Reflektionen niemals mit optischen Ger ten Lupe Mikroskop Fernglas Sicherheitshinweise Umgang mit Lasern der Klasse 2 Laserstrahlung Nicht in den Strahl blicken Laser Klasse 2 1 mW 650 nm EN 60825 1 2...

Page 5: ...ne Gewinde Dauermessung L ngenmessung Zwischenwerte Messwerte Messergebnisse Einheit m ft inch _ _ 1 2 1 2 1 2 TASTATUR Messen AN AUS Messebene Referenz hinten vorne Gewinde Einheit m ft inch _ _ 2 se...

Page 6: ...i starker Sonneneinstrahlung nicht verwendet werden Bei Messungen im Freien k nnen Regen Nebel und Schnee die Messergebnisse beeinflussen bzw verf lschen Bei ung nstigen Bedingung wie z B schlecht ref...

Page 7: ...messungen B x H x T 35 x 100 x 23 mm Gewicht 82 g inkl Batterien bis 10 m Messabstand bei gut reflektierender Zieloberfl che und Raum temperatur Bei gr eren Distanzen und ung nstigen Messbedingungen w...

Page 8: ...correct and proper use of the device Attention Do not look into the direct or reflected beam Do not point the laser beam towards persons If a person s eyes are exposed to class 2 laser radiation they...

Page 9: ...inuous measurement Length measurement Intermediate values Measurement values Measurement results Unit m ft inch _ _ 1 2 1 2 1 2 KEYPAD Measure ON OFF Measurement point reference rear front thread Unit...

Page 10: ...og and snow In unfavourable conditions e g with poorly reflecting surfaces the maximum deviation may be greater than 3 mm Carpeting upholstery or curtains will not reflect the laser optimally Measure...

Page 11: ...es without notice 19W47 Precision typical 2 mm Measurement range inside 0 2 m 20 m Laser class 2 1 mW EN 60825 1 2014 AC 2017 Laser wavelength 650 nm Beam divergence 1 5 mrad Operating conditions 0 C...

Page 12: ...757 Arnsberg Germany Tel 49 2932 638 300 Fax 333 www laserliner com LaserRange Master T2 Rev19W47 SERVICE Umarex GmbH Co KG Laserliner M hnestra e 149 59755 Arnsberg Germany Tel 49 2932 638 300 Fax 49...

Reviews: