The ThermoCamera Connect is used to visually display thermal patterns and enables non-contact
measurement of surfaces by evaluating the radiation in the infrared wavelength range via the integrated
non-chilled microbolometer. The imaging technology of the sensor provides a visual image of the
temperatures surrounding the inspected object. The temperature differences can be visualised by colour-
coding the individual temperatures in a thermogram with false colour display. Possible applications include
locating overloads in electrical components, detecting overheating in mechanical components, pinpointing
and analysing heating lines in walls and floors, assessing refrigerant and air conditioning systems and
much more.
Function / Application
Completely read through the operating instructions, the „Warranty and Additional Information“
booklet as well as the latest information under the internet link at the end of these instructions.
Follow the instructions they contain. This document must be kept in a safe place and passed on
together with the device.
!
General safety instructions
– The device must only be used in accordance with its intended purpose and within the scope of
the specifications.
– The measuring tools and accessories are not toys. Keep out of reach of children.
– Modifications or changes to the device are not permitted, this will otherwise invalidate the approval
and safety specifications.
– Do not expose the device to mechanical stress, extreme temperatures, moisture or significant vibration.
– The device must no longer be used if one or more of its functions fail or the battery charge is weak.
– Use only genuine accessories. Use of inappropriate accessories will invalidate the warranty.
– The charging progress can be viewed by briefly pressing the ON/OFF button.
– The residual charge of batteries with a weak charge is shown in red.
– The battery can also be charged while using the device.
– Disconnect the power pack from the mains when the device is not in use.
– Never use extension cables in conjunction with the battery charger, or similar accessories not approved
by the manufacturer, as this may result in a fire risk, the risk of an electric shock or injury to persons.
Safety instructions
Using electromagnetic radiation and RF wireless radiation
– Local operating restrictions – for example, in hospitals, aircraft, petrol stations or in the vicinity of
people with pacemakers – may apply. Electronic devices can potentially cause hazards or interference
or be subject to hazards or interference.
– The measuring accuracy may be affected when working close to high voltages or high electromagnetic
alternating fields.
– The measuring device is equipped with a wireless interface.
– The measuring device complies with electromagnetic compatibility and wireless radiation regulations
and limits in accordance with the RED 2014/53/EU.
– Umarex GmbH & Co. KG hereby declares that the ThermoCamera Connect radio equipment complies
with the essential requirements and other provisions of the European Radio Equipment Directive
2014/53/EU (RED). The EU Declaration of Conformity can be found in its entirety at the following
address: http://laserliner.com/info?an=AGR
– This device complies with the CE limit values for radiation exposure as defined for uncontrolled
environments. To avoid wireless radiation, this device should be used at a minimum distance of 20 cm
from the body.