PLMNL0232 REV. H Effective Date: 01/14/19
66
FiberCUT
®
2D Operation Manual
15 Appendix H
– Maintenance
COMPONENT
FREQUENCY
DESCRIPTION
Water & Gas
Lines
After performing any
maintenance
Inspect and replace any worn or damaged hoses.
See
Nozzle
Centering
After a Nozzle Change
Inspect and adjust as needed according to
Tip Centering
Camera
Every 3 months
Height
Sensing
After a Nozzle Change
Calibrate according to
After a Crash
As Performance Requires
After a Tip Touch
Pressure
Sensor
Once per day
Calibrate the pressure sensor according to
Entire Head
Monthly or more often if
needed
Clean the entire outside of the head, according to
Nozzle
Before EVERY shift
Inspect and replace as needed, according to
After a Tip Touch
After a Crash
Lower Cover
Glass
As Performance Requires
Replace the lower cover glass (PLLCG0060) according to
Lower Cover
Glass Seal
Monthly
Replace the lower seal (PLMSR0030) according to
Upper Cover
Glass
As Performance Requires
Consult a service specialist, proceed as directed
Upper Cover
Glass Seal
EVERY time you replace the
cover glass
Replace the upper cover glass and seal according to
Focus Lens
As Performance Requires
Consult a service specialist, proceed as directed
Replace the focus lens cartridge according to
Collimator
Cartridge
As Performance Requires
Consult a service specialist, proceed as directed
Replace the collimator lens cartridge according to