PLMNL0199 REV. J Effective Date: 08/05/21
8
FiberCUT
®
ST Operation Manual
Figure 14
3.3 Digital Inputs
Specifications: 5 to 24VDC, 10mA at
24V
The inputs are configurable for connection
to either sourcing or sinking outputs
depending on the connection made to the
input common.
3.3.1 Height Select Bits (HS1
– HS3)
The three discrete height select bits
activate seven standoff heights. When
all height select bits are off, the head
will return to its retracted position.
Note: The height select bits are only
operative if the analog input enable
(AIE) is off.
The
• symbol indicates ON.
HS1
HS2
HS3
STANDOFF
HEIGHT
•
0.5mm
•
0.75mm
•
•
1.0mm
•
1.25mm
•
•
1.5mm
•
•
1.75mm
•
•
•
2.0mm
Head Retracted
3.3.2 Teach / Center of Travel (COT)
The COT input sets the head in the
fixed center of travel position. When
teaching the motion system path, it is
preferable to have the FiberCUT
®
head in the COT position.
At the COT position, the decal on
the telescoping tube will have half
of the green section exposed. See
Figure 15
COT has precedence over HS1,
HS2 and HS3.