PLMNL0199 REV. J Effective Date: 08/05/21
18
FiberCUT
®
ST Operation Manual
3.9.3 Profibus
The connection to the Profibus I/O
uses a 5-pin micro connector located
on the bottom of the control box. See
Figure 21
PLCSA0017 Configuration
The FiberCUT
®
controller without an
external power switch consists of an
Allen Bradley 1734-APB Point I/O
module preconfigured to appear on
Node 12. Refer to Allen Bradley
Publication 1734-UM005B-EN-P for
more information on configuring the
module.
The 9-pin connector of the Profibus
module includes a termination switch.
The FiberCUT
®
controller ships with
this switch in the OFF position. See
If this device is not the last node in
the system, then the termination
switch remains OFF.
If this device is the last node in the
system, it is necessary to turn the
terminating switch ON.
Figure 22
PARAMETER
VALUE
Input Size (Bytes)
1
Output Size (Bytes)
1
SLOT
DESCRIPTION
MODULE
TYPE
1
Digital Inputs
1734-OB8
2
Digital Outputs
1734-IB8
PLCSA0045 Configuration
The FiberCUT
®
controller with an
external power switch consists of a
HMS Industrial Networks Anybus IC
PDP module and Interconnect Board.
Set the Node Address using the rotary
switches S1 (x10) and S2 (x1) on the
Interconnect Board to addresses
ranging from 01-99.