To reinstall the manifold seal:
4. Verify that the bottom of the shroud,
especially the lip area, is clean.
5. Press the manifold seal (PLMSR0022)
against the shroud along the lip until
the entire seal is pressed against the
inside of the shroud.
No adhesive is used to install the
seal.
There is a “smooth” side and a
“fuzzy” side to the seal. The
“smooth” side is pressed against
the lip area of the shroud. The
“fuzzy” side creates a dust barrier
between the main body and the
shroud.
The ends of the seal, cut at a 45°
angle, must meet together without
any gaps.
An appropriate sharp tool may be
helpful.
Figure 67
6. Screw the shroud back onto the main