ICS-6 Instruction Manual
01000-53-000
Page 10 of 42
Issue 11 19 January 2021
5
Wiring
Warning.
This unit operates from mains electricity. There is mains voltage on the circuit boards and
some of the terminals. Always disconnect the mains power supply before opening the unit or
attempting any wiring alterations.
The ICS-6 is a versatile interlock system and there are a variety of ways in which it can be used. Be
sure you know which configuration you require before you attempt to wire the unit. If you require
further assistance, please call Lasermet technical help. Contact details are at the end of this manual.
All connections are made to plug-in terminals on the narrow circuit board located in the bottom half
of the case. It is usually easiest to unplug the terminals while the connections are being made. A
2.5mm slotted screwdriver will be needed to access the smaller terminals.
5.1 Mains In
5.1.1
ICS-6
(110V to 240V ac 50-60Hz)
The ICS-6 has a universal mains voltage input and does not need setting for different supply
voltages.
It is recommended that a circuit breaker or other external switch is provided for the mains supply to
the unit depending on the amount of additional equipment connected to the ICS-6. This should be
mounted in a suitable location which can be easily reached. We recommend that a switched fused
spur (fused between 3A and 8A) with neon indicator is provided. In all cases the supply must be
protected by an overcurrent device not exceeding 8A.
Wire the incoming mains power to the following terminals on the narrow circuit board in the
bottom of the case:
Live
-
L IN
Neutral
-
N IN
Protective Earth
-
PE
Note
.
The protective earthing cable connection is required.
Note. Only terminals J11 and J12 (IO1 and IO2 respectively) on the ICS Interlock Board are for
primary voltage.