ICS-6 Instruction Manual
01000-53-000
Page 23 of 42
Issue 11 19 January 2021
LASER
Interlock
Input 1
INTERLOCK
OPERATORS
Distribution
Box
8-Core
Lead
Plug
OUTPUT
MONITOR
J14
A
A
B
B
Interlock
Input 2
Laser Saf e
Contact 1
Laser Saf e
Contact 2
ICS-6
5.4.4
Electro Magnetic Door Locks
Use only fail-safe door locks provided by Lasermet (electric door strikes or maglocks). These will
prevent access to the room while the laser is on while always allowing people to enter or leave the
room in the event of a power loss. In order to ensure that people can always enter or leave the
room in the event of an emergency it will be necessary to put an emergency stop or break glass
switch near each door. If in doubt call Lasermet technical help.
The door should be fitted with interlock switches (see section 5.2) so that the laser is disabled if a
door is opened using the break glass switch.
Magnetic Door Lock
set to 24VDC
Supply
+24V
+24V
+12V
+12V
0V
0V
INTERLOCK
OPERATOR
1, 2 OR 3
DC
POWER
OUT
Internal
Em ergency
Door Release
Breakglass
Protection Diode,
see text.
External
Emergency
Door Release
Breakglass
-
+