Specifications
Safety Performance
Up to PL‘e’ to EN ISO 13849-1:2015 see section 3.
Shutdown Time
6ms typical.
Measured from opening of safety circuits to opening of interlock
operator contacts
Supply Voltage
110 - 240VAC 50 - 60Hz, universal input
24VDC, for ICS-6-24
Power Consumption
15W typical (ICS-6 only)
Internal DC Power Supply
24V 3A maximum
12V 1A maximum, derived from the 24V supply
No. of Output Contacts
3 (standard)
9 (9-way upgrade option)
Output Contact Rating
6A, 240VAC / 50VDC resistive load (standard)
8A, two at 240VAC / 50VDC, seven at 50VAC / DC (9-way option)
Safety Circuit Fuse Rating
315mA
Ingress Protection
IP50
Operating Conditions
0° to 55°C, 0% - 95% relative humidity non-condensing
Size
263mm wide X 233mm high X 89mm deep (standard)
263mm wide X 233mm high X 145mm deep (deep box)
Weight
1.7kg (standard)
Dimensions are approximate. Values given as ‘typical’ are average values measured across a number
of samples and are not guaranteed. Lasermet reserve the right to alter any specification without