background image

LS-100-12 Laser Beam Shutter Instruction Manual 

 

CEB00XXX-53-000 

 

Issue 4          19 January 2021 

 
 

 
 

LASERMET  

LS-100-12 SHUTTER 

 

INSTRUCTION MANUAL 

 

 

 

GRAVITY FED, FAIL-SAFE LASER BEAM SHUTTER 

FOR SAFETY APPLICATIONS 

 

 

 
 
 
 

Summary of Contents for LS-100-12

Page 1: ...LS 100 12 Laser Beam Shutter Instruction Manual CEB00XXX 53 000 Issue 4 19 January 2021 LASERMET LS 100 12 SHUTTER INSTRUCTION MANUAL GRAVITY FED FAIL SAFE LASER BEAM SHUTTER FOR SAFETY APPLICATIONS ...

Page 2: ...B00XXX 53 000 Page 2 of 9 Issue 4 19 January 2021 LASERMET LS 100 12 Instruction Manual Contents 1 Declaration of Conformity 3 2 Safety Warnings 4 3 Concept 5 4 Installation 5 5 Wiring 5 6 Operation 6 7 Specifications 7 8 Warranty 8 9 Contact Details 9 ...

Page 3: ...nd standards and found to comply Lasermet certifies that this product complies with the basic requirements for health and safety as provided by the following directives and standards Directives Machinery Directive 2006 42 EC Standards EN 60825 4 2006 A1 2008 A2 2011 Safety of Laser Products Part 4 Laser Guards The relevant Protective Exposure Limits are Irradiated Area PEL T2 100s 4 mm2 5 MW m2 10...

Page 4: ...ay be made to tamper with the parts open them or use them outside of the parameters contained herein The units are only designed to be fixed to surfaces using their inbuilt fixing holes They must not come into contact with each other or any other moving part when in use The parts should never be subject to impact or mechanical strain Safety switches should never be defeated or bypassed It is imper...

Page 5: ...ings electrical power or any other drives or devices for return to the safe mode Lasermet provides a full range of laser interlock equipment including control systems interlock switches illuminated warning signs laser shutters door locks external power supplies etc which can be connected to provide a complete laser interlock system Full support design and installation is available from Lasermet pl...

Page 6: ...at the shutter is fully closed Pressing the green button momentarily will open the shutter The Orange LED will light indicating that the shutter is fully open and the beam is exposed To manually close the shutter press the red button Loss of power to the shutter such as when a door interlock switch trips the interlocked power supply will also cause it to close Alternative Switching Configurations ...

Page 7: ...tions Supply Voltage 12 24VDC Current Consumption 200mA max Status Output Voltage As incoming supply Status Output Current Rating 100mA max non inductive Optical Specification Maximum Optical Power 20W ave Maximum Beam Diameter 50mm Maximum Power Density as per DoC Dimensions are approximate Values given as typical are average values measured across a number of samples and are not guaranteed Laser...

Page 8: ...ainst defects in workmanship for 12 months Damage or defects caused by other factors are not covered For example industrial contamination incorrect cleaning storm damage Consequential loss is not covered under warranty Compensation for indirect or direct loss or damage is expressly excluded Rectification of the defects or a replacement does not initiate a new warranty period For all deliveries pay...

Page 9: ...cted to provide a complete system We also supply equipment and consultancy covering all aspects of laser safety Full support design and installation is available from Lasermet please contact us for any queries For sales and technical support Lasermet Ltd Lasermet House 137 Hankinson Road Bournemouth BH9 1HR United Kingdom Tel 44 0 1202 770740 Fax 44 0 1202 770730 Email sales lasermet com Website w...