NOTE
: If you wish to use Border and Cluster, then the border must be less than the
distance specified in the Cluster setting.
C. Advance Setting
C-1 Scaling
Scaling function enables you to adjust output inaccuracy when you find the actual output scale
is different from what you set in the computer, you can use scaling function to modify it and get
a perfect one. Positive value is to enlarge the size, negative is to reduce size. For examples,
adjust the scale by +10 to enlarge the object’s size by 10/1000.
C-2 Position mode options
Home:
Focus carriage goes back to the upper right position after finishing a job.
Without Home:
Focus carriage stops at the last position of a data file. You can
engrave inside a bowel or a concave object to prevent hitting the object.
Relative Move:
You can place the focus carriage at any place you want to start a job.
When finishing a job, the focus carriage will move back to the starting point. You can
engrave inside a bowel or a concave object to prevent hitting the object.
Center Mode:
The laser will recognize whenever location the lens carriage (the red
beam) is anchored as the center of the to-be-engraved graphic.