BL57-NE
(E)
3-9
B
A
A
B
Spacer
B
A
A
B
Spacer
7
Fasten scale clamps on both ends of the scale with the same torque. (Final fastening torque: 1.4 N
·
m)
Fig. 3-11
8
Check the surface of the scale for oil and dust. If the surface is dirty, wipe it clean with gauze moistened
with alcohol. Be sure to wipe off oil and dust on the surface thoroughly.
3-4. Detector Head Mounting
1
Move the machine table and adjust the mounting position of the detector head to roughly the center of
the scale.
2
Use the supplied mounting screws to semi-tighten the detector head.
Fig. 3-12
BL57-016NE, 036NE, 037NE, 042NE, 056NE, 066NE, 076NE, 086NE, 096NE, 106NE
BL57-026NE, 027NE, 032NE, 046NE
Scale
Scale clamp
Reference
plate
Detector head
Scale
Detector head
Detector head mounting screw
(M2
×
12 hex. socket-head cap screw)
Plain washer (nominal 2)