3-3. Scale Mounting
1
Check that there is no dust or other foreign substances on the mounting surface, and mount the reference
plate parallel to the machine guide as shown in the figure. (Fastening torque: 1.4 N
·
m)
The reference hole is located on the left, as shown in the figure. Adjust at the right side while observing
the parallelism with the lever type dial gauge.
Fig. 3-5
The scale is pressed against the reference plate for parallelism when mounting. The reference plate is
vital to accurate scale mounting. Be sure to always use the supplied screw and mount it exactly as
described in the specifications.
Fig. 3-6
BL57-003RE, 011RE, 016RE,
BL57-006RE, 026RE, 031RE, 046RE
021RE, 036RE, 041RE
Note: “M” refers to the machine guide.
BL57-003RE to 046RE
BL57-056RE to 106RE
BL57-056RE, 066RE, 076RE, 086RE, 096RE, 106RE
0.01 (0.00039") M
+
0.05
Reference ø4
0
M4
×
8
Plain washer (nominal 4)
Reference abutment
surface
M4
×
8
Plain washer
(nominal 4)
Reference abutment
surface
M4
×
8
M4
×
8
Plain washer (nominal 4)
Plain washer
(nominal 4)
Reference abutment
surface