5. Scale Signal Output
5-1. A/B Signal and Alarm Output Specifications
(For output formats F and G)
•
The output specifications are compliant with EIA-422.
•
A/B signal minimum phase difference t : 38 ns
Fig. 5-1
•
An error of about 38 ns is generated due to the synchronization of the A/B signal by the
26.3 MHz internal clock.
•
The minimum phase error can vary depending on the length of the output cable, cable capacity, receiver
load, and other factors.