COD. 83119L.01EN
09//2016
25
IF IN THE DISPLAYS YOU CANNOT SEE THE PARAMETERS WE HAVE INDICATED OR THE
PUSH-BUTTONS DO NOT PROVIDE ACCESS TO THE INDICATED FUNCTIONS IN THIS MANUAL,
IT COULD BE POSSIBLE THAT DURING THE HANDLING OF THE PANEL CONTROL THE
KEYBOARD CONFIGURATION HAS BEEN CHANGED.
The keyboard configuration is changed by pressing at the same time for a long time the buttons
and
,
it will be correctly configured when it appears in the display on top“110”
6.1 USER MENU 1
We call “USER MENU 1” to all the options the user can access from the “Main display” (the one that is displayed
without pressing any button).
All buttons have a double function. One function is activated with a
“clic”
(short keystroke) and the other one is
activated with a
long keystroke
.
6.1.1
- INFORMATION
With every
“clic”
of the button
, we see in the display that is below the abbreviation of the name of parameter
and in the display on top their value.
The parameters to visualise in order of appearance are:
tF
:
Fumes temperature (ºC).
tA
:
Room temperature (ºC).
FL
:
Air primary speed.
UF
:
Combustion fan speed (rpm)
Co
:
ON auger time (sec).
St
:
Remaining time for Extraordinary Maintenance (h).
St2
:
Remaining time for Ordinary Maintenance (h).
FC
:
Code and revision firmware FYSYI01000033.X.Y.
494
:
Manufacturer code item: 0Y.0X.
If we stop pushing the button for 5 seconds, the system returns to the main screen.
6.1.2
- ERROR RESET, TURN ON AND TURN OFF THE STOVE
If we push
for some seconds
the button
, we will change the state in which the stove is at that moment. The
states of the stove can be:
CURRENT STOVE STATE BEFORE PUSHING
STOVE STATE AFTER PUSHING
(long keystroke)
OFF
(alarm activated)
OFF
(No alarm activated)
OFF
(No alarm activated)
IGNITION
IGNITION, NORMAL, MODULATION or STAND-BY
SHUTDOWN
(“OFF”)
SHUTDOWN
(“OFF”)
“REC”
(Ignition recovery)
“REC”
(Ignition recovery)
SHUTDOWN
(“OFF”)