COD. 79101EN.00
11/2013
24
6.3 LOADING THE PELLETS
The load of fuel is made through the upper side of the boiler. Pour the pellet in the tank.
Never remove the protection grille inside the tank. During the load, prevent the sack of pellet
from contacting hot surfaces. Fill the tank only with the fuel that meets the aforementioned
specifications.
6.4 IGNITION OF THE BOILER
Press the button ON/OF
during more than 3 seconds, the boiler will pass to mode on, on the screen will appear
the word “FIRE”.
Subphases “ON”:
The start phase is composed by 5 phases which occur in the following order: “CLEANING”, “LOAD”,
“PAUSE”, “WAITING FLAME” and “FLAME STABILIZATION”. These phases are described below.
6.5 CLEANING
Burner cleaning phase. The burner motor is working for a defined time and the fume motor at a defined speed.
6.6 LOAD
Continuous load of fuel into the burner, preheating of the resistor. The burner motor turns off, while the fume motor
continues running at the defined speed.
6.7 PAUSE
Loading auger still, fume motor at the defined speed and resistor on.
6.8 WAITING FOR THE FLAME
Waiting phase when the ignition must take place; the auger motor starts working again for a defined time. The
transition to the next phase is permitted when the fumes temperature exceeds the threshold and during the next 90
seconds there is an increase of 3 ° C of such temperature. If such increase does not occur in the first 90 seconds,
other records are made, always in intervals of 90 seconds, until it reaches an increase of at least 3 ° C; all within a
time limit defined by a parameter. If the waiting for the flame phase does not come to fruition, the alarm of "
FAILED
IGNITION
" will be activated. During this phase, the fume motor rotates at a defined speed.
6.9 FLAME STABILIZATION
Stabilization phase after the presence of the flame with an intermediate load of fuel. The fume motor, at a defined
speed, and the auger, at a defined speed, are active while the resistors for the ignition of the flame are off.
6.10 IN OPERATION
Phase of regular operation of the burner with a variation of the power from 1 to the maximum programmed in
function of the temperature of the boiler. The modulation of the operating conditions is made according to the
parameters.
During this phase 3 types of control take place:
Temp. Control. Maximum fumes:
if the maximum temperature of the fumes is exceeded, the auger starts working
in regimen 1.
Summary of Contents for BIOSELF
Page 1: ...COD 79101EN 00 11 2013 BIOSELF MULTIFUEL BOILER USER AND INSTALLATION MANUAL...
Page 2: ...COD 79101EN 00 11 2013 2...
Page 4: ...COD 79101EN 00 11 2013 4...
Page 38: ...COD 79101EN 00 11 2013 38...
Page 40: ...COD 79101EN 00 11 2013 40...
Page 41: ...COD 79101EN 00 11 2013 DATE WORKING HOURS INTERVENTION TAS SIGNATURE USER SIGNATURE...
Page 42: ...COD 79101EN 00 11 2013 42 DATE WORKING HOURS INTERVENTION TAS SIGNATURE USER SIGNATURE...
Page 43: ...COD 79101EN 00 11 2013 43 DATE WORKING HOURS INTERVENTION TAS SIGNATURE USER SIGNATURE...