Recommendation:
Check out conditions of blades every 40 operating hours.
Regrind blade edges if they are found blunt
Jointing elements (bolts and nuts) should be replaced together with The
blades exchange. Safety nuts should be used only once, since they lose
their self-locking properties if used repeatedly. The fixing bolts should
be tightened with torque of
100 Nm
NOSTRESS System – Speed Regulation
This system is intended for overload
protection of the combustion engine
consisting of an electronic control unit and a
speed sensor installed on the rotor shaft.
Control unit:
This control unit displays actual rotor speed
values. When the rotor stops, the unit
displays a total number of running hours
"TH" or a daily number of running hours
“DH”. To reset the current daily number, just
press both arrow buttons
together, set up
the access code to “3003” and enter the main user menu. Select the submenu
“delete daily hours” and confirm the function “delete”.
Right function of NOSTRESS system:
The speed regulator reduces material feeding upon contingent overloading. For
example, the chipping wheel speed is set to 900 (1100) rpm to turn the loading
rolls off at speed loss and to 910 (1110) rpm to turn the rolls on again. Actual rotor
speed values are displayed on the control unit. However, actual engine speed
values are not displayed.
This control unit enables to set the speed according to the material to be loaded:
F1 – light branch-wood, shrubbery, twigs, hedges
Summary of Contents for LS 160
Page 1: ...Orig version 11 2016 OPERATING INSTRUCTIONS CHIPPER LS 160 model LS 160T...
Page 5: ...Chipper LS 160T 5...
Page 6: ...Chipper LS 160T 6...
Page 52: ...Chipper LS 160T 52 Service Report...
Page 53: ...Chipper LS 160T 53 Hydraulic scheme...
Page 54: ...Chipper LS 160T 54 ELEKTRICK ZAPOJEN ELEKTRISCHE SCHEMA WIRING DIAGRAM...
Page 55: ...Chipper LS 160T 55 ELEKTRICK ZAPOJEN ELEKTRISCHE SCHEMA WIRING DIAGRAM...