- 7 -
CD-
Elementy systemu domofonowego
2500
2, 4, 8, 16, 32, 64, 128
To program the uniphones, use suitable jumpers on the uniphone programming
connector. These jumpers should be installed for which the sum of their numerical
values is equal to a number of a given uniphone. Numerical values of the jumpers
and version of series are shown on the printed circuit board. Example: to obtain
uniphone number equal to 12, install jumpers on connectors 4 and 8 (4+8=12); to
obtain uniphone number 45, use connectors 1, 4, 8, 32 (1+4+8+32=45).
NOTE:
Do not program 0 As this setting is not included in the program it may may result
in malfunctioning of the program.
3.4. Connecting uniphones to electronic cassette.
Terminals marked L- L+ are designed for connection of the uniphones to the electronic
cassette. All uniphones in the system are connected to the same two-wires conductor
in parallel. 255 uniphones LF-8 or LX-8 may be connected to the line. Prior to
connecting the uniphone line make sure that the line is not short-circuited. The line
resistance (measured by means of a digital meter) should be at least 100 kiloohms.
Generally, the system is resistant to possible short-circuiting occuring during both
installation and operation. The electronic circuit, however, should not be operated
under short-circuit conditions during a long time as high shortücircuit current results
in increased heat emission and this may disadvantageously affect the system
operation reliability. If the uniphone line is short-circuited during the system operation
error message E-2 is displayed and no call is possible. In this case coded locks
can be used. Connecting the uniphones, pay attention to proper polarity of the line.
For this reason it is recommended to use cable with coded wires.
3.5. Conecting system power supply.
With the electronic cassette and uniphone line connections checked, the system
power supply may be connected. Use the transformer supplied with the system.
It has two secondary windings, one of them designed for supplying the electronic
cassette. This winding has two outputs:
-12V/0.8A -used for 220V +/- 10% mains voltage
-14V/0.8A -used for the mains voltage lower than 220V-10%=198V.
The second secondary winding is used for supplying electric lock catch. It produces
12V/0.8A After the power supply switching on the system counts a time provided
for stabilization of the uniphones (approx. 25s). After the stabilization time the
system is ready for operation. The
stabilization time is counted each time the power supply is switched on. Additionally,
lock is switched on for a moment for test. When time counting is completed, a dot
is displayed at the display right side. The door phone is ready for operation.
Each time the power supply is switched on, a procedure of restoration of predefined
code table can be called by touching fields C+ simultaneosly provided, however,
this function has not been disabled by the program. Refer to section dealing with
the system programming for details.
All manuals and user guides at all-guides.com
Summary of Contents for CD-2000
Page 34: ...32 CD Elementy systemu domofonowego 2500 All manuals and user guides at all guides com...
Page 35: ...33 CD Elementy systemu domofonowego 2500 All manuals and user guides at all guides com...
Page 36: ...34 CD Elementy systemu domofonowego 2500 All manuals and user guides at all guides com...