2.3 Electrical Requirements
WARNING
- Electrical wiring and grounding of the unit should be done in accordance to the applicable
local, state and federallaws and regulations.
- The ice machine must be grounded in accordance to the law and regulations of the country,
state, and region.
Read the following warnings
- The ice machine must be grounded.
- The ice machine must be connected to an exchangeable fuse or circuit breaker.
- Decide the appropriate size of the wire based on the length, thickness, and position of the wires.
- Electrical wiring and ground must be done by a qualified electrician.
●
Installation condition
Condition
Minimum
Maximum
Ambient Temperature
°
F
45
100
°
C
7
38
Water temperature
°
F
45
90
°
C
7
32
Water pressure
psig
30
100
kPa
206.8
689.4
Voltage
115V
100
130
220V
208
230
2.3.1 Voltage
2.3.2 Fuse / Circuit Breaker
- When operating the ice machine (with maximized electrical load) range of variation in maximum
voltage allowed is ±10% of the rated voltage.
-Main voltage transformer tab switch must be set to the same input voltage for single phase models,
650A, 900A.
- The ice machine must be wired to an exclusive fuse/circuit breaker
- The circuit breaker must be installed in accordance with applicable local, state and federal regulations.