background image

15

MEMO

Summary of Contents for LMT27

Page 1: ...s Installation Operation Manual Please read this manual completely before attempting to install or operate this equipment R512B 252 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS Visit us on th...

Page 2: ...rior of the package and skid or container Any damage should be noted on the delivery slip and reported to seller immediately 2 If damaged open and inspect the contents with the carrier 3 WITHIN 48 HOU...

Page 3: ...sions Including 4 Casters mm W 700 923 1227 1533 1839 D 762 762 762 762 762 H 912 912 912 912 912 Net Weight kg 61 74 87 103 120 Type of refrigeration system Indirect cooling Fan blowing Control Therm...

Page 4: ...LUCR60 D4 LUCR72 D6 Capacity Liter 200 372 474 572 Exterior Dimensions Including 4 Casters mm W 700 1227 1533 1839 D 762 762 762 762 H 912 912 912 912 Net Weight kg 66 108 126 150 Type of refrigeratio...

Page 5: ...uding 4 Casters mm W 700 923 1227 1533 1839 D 762 762 762 762 762 H 912 912 912 912 912 Net Weight kg 64 78 91 108 124 Type of refrigeration system Indirect cooling Fan blowing Control Thermostat Numb...

Page 6: ...62 762 762 H 1082 1082 1082 1082 1082 Net Weight kg 67 82 100 112 129 Type of refrigeration system Indirect cooling Fan blowing Control Thermostat Number of Shelves 1 2 2 2 3 Number of doors 1 2 2 2 3...

Page 7: ...72 D6 Capacity Liter 200 372 474 572 Exterior Dimensions Including 4 Casters mm W 700 1227 1533 1839 D 762 762 762 762 H 1082 1082 1082 1082 Net Weight kg 72 121 135 160 Type of refrigeration system I...

Page 8: ...ting board 901 H 1122 1122 1122 1122 1122 Net Weight kg 76 92 110 123 141 Type of refrigeration system Indirect cooling Fan blowing Control Thermostat Number of Shelves 1 2 2 2 3 Number of doors 1 2 2...

Page 9: ...OR USAGE ONLY This equipment is intended for indoor use only 5 STABILIZING Make sure the unit is installed on a solid surface with the front wheels locked while in use 6 LEVELING Make sure that the un...

Page 10: ...ct power to unit Take off rear cover at the bottom by removing screws Clean off accumulated dirt from condensing coil and fan blades with a soft brush Make sure to brush in the direction of the fins a...

Page 11: ...preset to NORMAL at the factory 3 Set the control knob toward COOL for higher temperature and COLD for lower temperature 4 The thermostat controls compressor s ON OFF by sensing inside temperatures of...

Page 12: ...The door is opened too frequently Loading of too much warm or moist product Not enough ventilation Move the unit in a well Ventilated place with at least 7 Inches of clearance on all sides Condenser i...

Page 13: ...13 Installing Casters 1 Remove the outer packing 2 Install the castors as illustrated 3 Maker sure that the castors with brakes are installed at the front of the unit...

Page 14: ...14 MEMO...

Page 15: ...15 MEMO...

Page 16: ...Manufacturer DAEYEONG E B ANSAN SI GYEONGGI DO REPUBLIC OF KOREA TEL 82 31 491 1091 FAX 82 31 491 0325 www daeyeong co kr...

Reviews: