8 MENù INSTALLER SETTINGS
The following instructions are intended only for technical personnel specialised in heating units manufactured by
COLA.
Changing the parameters in a non-appropriate way can cause serious damage to
people, the units and the environment. In this case, Cola s.r.l. declines any liability.
To access the INSTALLER SETTINGS menu, press button P3 - MENU and use the scroll buttons to display the item
INSTALLER SETTINGS and then press button P3 - MENU. Use the scroll buttons to display access key 10 and
press button P3 - MENU.again.
The various parameters can be displayed with the scroll buttons; access with button P3 - MENU, edit them with the
scroll buttons and exit with ESC.
It contains the adjustment parameters given below.
Parameter code
Description
10-01
For increasing or decreasing auger OFF duration for all powers.
10-02
For increasing or decreasing fume extractor speed for all powers, by a
value of 5% for each unit.
10-03
Enable key lock.
10-04
Adjustment probe temperature setting ON/OFF delta (see parameter
10-07)
10-05
Stove shutdown delay.
Valid only in case of Standby set to ON.
10-06
For enabling self-calibration.
10-07
For selecting the probe on which stove adjustment is to be set:
- LOCAL PROBE: probe on stove and connected to the mainboard.
- REMOTE PROBE: probe located on the remote graphic display.
"direzione e coordinamento della Ferroli spa"
The Manufacturer reserves the right to make technical or aesthetic changes to the products at any time without notice.
The drawings, measurements, diagrams and any other configurations are given only by way of example.
Summary of Contents for Alba
Page 2: ...ALBA 2...
Page 3: ...ALBA 3...
Page 5: ...ALBA 5...
Page 6: ...ALBA 6...
Page 7: ...ALBA 7...
Page 8: ...ALBA 8...