TERMO-VIOLA
43
2.2
Place of installation, positioning and fire-prevention safety
The place of installation must be sufficiently ventilated to allow the removal of any combustion smoke leaks.
The unit is suitable for operation in domestic environments with min. temperature of 0°C; it comes complete with an
antifreeze function that activates the heating pump for system water temperatures below 6°C, safeguarding: the
heating chamber, heating/DHW circuit. The antifreeze function is active only when the stove is electrically powered.
To prevent the risk of fire, the structures surrounding the stove must be protected from the heat. For example, floors
in wood or flammable material must be suitably protected with steel panels or toughened glass. Any wooden boards
or beams above or crossed by the flue must be suitably protected in conformity with the requirements of the specific
current installation standards. Suitable fire-prevention devices should be arranged for any eventuality.
The minimum front distance for the protection of flammable objects is 1.5 m. The minimum safety distances from
flammable materials must be at least 0.2 m and in any case comply with the following table:
Every installation must provide for an easily accessible technical space for periodical maintenance.
The stove is provided with 4 adjustable feet to facilitate positioning on not perfectly flat floors. To adjust the height,
tilt the stove slightly and turn the feet as required.
The stove is supplied with the ambient sensor fixed through a wrapper on the back of the stove; we recommend to
remove the wrapper and to locate the sensor in the best position possible as to improve the temperature registration
in accordance with the ambient context and the length of the cable.
As for temperature registration done at a certain distance we reccomend to install the ambient thermostat/ambient
programming clock-thermostat
– see. par.4.8.
-The stove cannot be installed in bedrooms, bathrooms and in general in rooms where another heating
unit , is already installed without an independent air inflow.
- With wooden floors, install a floor protection base in conformity with the current regulations.
- Suitable fire prevention devices should be arranged for any eventuality.
- Do not install the stove in places with an explosive atmosphere.
Floor protection base
Wall air inlet
min. 100 cm²
A
=
200
mm
B
=
200
mm
C
=
1500
mm
D
=
200
mm
Antiwind
grille
Flue
Inspection door on
flue
T union with
inspection cap
Flue connection
Summary of Contents for TERMO-VIOLA
Page 2: ...TERMO VIOLA 2 ...
Page 3: ...TERMO VIOLA 3 ...
Page 5: ...TERMO VIOLA 5 ...
Page 6: ...TERMO VIOLA 6 ...
Page 7: ...TERMO VIOLA 7 ...
Page 8: ...TERMO VIOLA 8 ...