To connect the heating stove to a DHW system it is advisable to contact a competent technician
in order to best
optimise the plumbing connections and the performance of the entire system without compromising stove operation.
For the connection to the DHW circuit it is necessary to install a monostable 3-way valve outside the stove whereas
the circuit is not functional with the DHW pump.
To connect the DHW system 3-way solenoid valve it is necessary to request the optional: supplementary electronic
board model ‘I055’ for management of commands as well as possible software upgrading.
During stove transport the gaskets in the plumbing system may come loose and/or break, causing water
leaks during normal operation; therefore make sure to check the tightness of the circulating pump and
heating chamber connection rings and vent the residual air during water filling and after the first hours of
operation.
Water supply
F1/2”
Pmax 2 bar
Arrangement
PLUMBING CONNECTIONS
on back of stove
KEY
Drain cock
Pressure sensor / Pressure gauge
Non-return valve
Circulating pump
Membrane pressure vessel
Shutoff valve / Cock
Circuit / heating chamber air ven
Valves to be included in system during
installation
– not supplied with the unit
Safety valve P max 3 bar
Safety sensor T > 85°C
Water temperature sensor
Circuit pressure sensor