Maintenance
Every 8 Operating Hours
5
5-2
Lastec//021819
Maintenance
CAUTION!
Always perform the appropriate maintenance checklists at the proper time interval.
Failure to perform the appropriate maintenance checklists at the proper time interval
will cause damage to the Articulator, unsafe operating conditions and substandard
performance.
Warranty issues are dependent on proper maintenance.
Along with completing the Pre-Operation Equipment Inspection Checklist
each time
you
operate the Articulator, complete the following Maintenance Checklists at the indicated
time intervals.
5.1
Every 8 Operating Hours
Complete the Pre-Operation Equipment Inspection Checklist.
Grease all grease zerks.
Verify all hardware is functional, securely fastened and in good condition.
Grease all wheel hubs.
Grease the PTO shaft collar and both cross bearings.
Inspect all belts for cracks, wear, or damage; replace as needed.
Inspect the spindle bearing grease seals (under each deck) for grease leakage or
improper seating.
Inspect gearbox and seals for leaks.
Verify that the split-tapered bushing bolts mounted in the drive pulley under the
gearbox are tight.
(Torque to 96-120 in.lbs)
Lubricate all joints and moving parts which are not equipped with grease fittings.
(
Recommend the use a nickel-based anti-seize for these areas).
Inspect entire Articulator for loose or entangled parts, debris, obstructions, mis-
placed tools, or any other possible safety hazards, equipment hazards or projectile
hazards. Clean off decks of any dirt, grease or oil.
Clean and gauge wheels to reset the bearing pre-loads. (Reference Service Bulletin
SB-0149)
Caution
Summary of Contents for 100EFK
Page 1: ...100EFK Lastec Mower Owner s Manual Manual Part Man 100EFK ...
Page 5: ...Lastec 021819 1 1 1 SECTION 1 TO THE OWNER ...
Page 12: ......
Page 13: ...Safety Information Safety Information Lastec 021819 2 1 2 SECTION 2 SAFETY INFORMATION ...
Page 25: ...Initial Set Up Initial Set Up Lastec 021819 3 1 3 SECTION 3 INITIAL SET UP ...
Page 38: ...Lastec 021819 4 1 4 SECTION 4 OPERATING PROCEDURES ...
Page 46: ...Operating Procedures Anti Scalp Wheel Adjustment 4 4 9 Lastec 021819 Operating Procedures ...
Page 47: ...Maintenance Maintenance Lastec 021819 5 1 5 SECTION 5 MAINTENANCE ...