background image

www.lastolite.com

Lastolite 

Lastolite

Lumen8 F200 

Lumen8 F400

Stored Energy

200 w/s

400 w/s

Guide Number (m/100iso)

42

60

Recycling Time (100%)

0.3 ~ 0.9 sec

0.4 ~ 1.6 sec

Flash Duration

1/700 ~ 1/1700 sec

1/700 ~ 1/1700 sec

Flash Power

Full ~ 1/32nd

Full ~ 1/32nd

Power Control (stepped rotary dial)

1/10th F’Stops

1/10th F’Stops

Body Construction

Metal casing with

Metal casing with

plastic control panel

plastic control panel

Unit Colour

All Black

All Black

User Replaceable Flash Tube

No

No

Modelling Lamp

250w

250w

Modelling Lamp Modes

Full, Prop, Off

Full, Prop, Off

Auto Dump

Yes

Yes

Colour Temperature

5300 ~ 5600k

5300 ~ 5600k

Slave Cell

Yes (10 metres)

Yes (10 metres)

Triggering Methods

Sync, Test, Slave

Sync, Test, Slave

Main Operating Controls

Rocker Switch

Rocker Switch

Sync Voltage

4v DC

4v DC

Voltage Stabilisation

+/- 1%

+/- 1%

Fan Cooled

No (not required)

No (not required)

Thermal Cut Off

Yes (x2)

Yes (x2)

Ready Light

Yes

Yes

Audible Recharge Confirmation

Yes

Yes

Operating Voltage

170 ~ 240v

170 ~ 240v 

50 ~ 60Hz

50 ~ 60Hz

Umbrella Fitting

8mm

8mm

Fuse rating

6 amp

6 amp

Spare Fuse Supplied

Yes

Yes

EM Noise Supression

Yes

Yes

Length x Width x Height (mm)

410 x 182 x 210mm

410 x 182 x 210mm

Weight

2.3kg

2.5kg

Mounting System

‘S’ Type compatible

‘S’ Type compatible

Summary of Contents for lumen 8

Page 1: ...User Manual...

Page 2: ...ctor 2 Reflector Release Button 3 Slave Cell 4 Lighting Stand Clamp 5 Clamp Screw 6 Umbrella Clamp Screw 7 Umbrella Clamp 8 Reflector Umbrella Slot 9 Inner Reflector 10 Flash Tube 11 Reflector Bayonet...

Page 3: ...Power Socket 14 Fuseholder Fuses 15 Power On Off 16 Modelling Lamp On 17 Modelling Lamp Full 18 Slave Cell On 19 Beeper Sounder On 20 Flash Test Button 21 Ready to Fire Indicator 22 Flash Modelling P...

Page 4: ...th one hand while adjusting the tilt with the other OPERATING PRECAUTIONS SAFETY The F200 400 units are designed for indoor use only and for connection to domestic 220 240VAC single phase only The uni...

Page 5: ...sory if it is possible Line up the reflector bayonets over the slots as shown If an umbrella reflector is also going to be used orientate the reflector so that the oblong reflector slot is at the bott...

Page 6: ...are when fitting a lamp 11 The ES screw socket may require the lamp to be fully screwed down in order to make contact If a new lamp fails to light check that it is fully screwed down 12 Take care not...

Page 7: ...his function the photographer can easily check from the camera position that all units have flashed When the Full switch is switched up the modelling lamp function changes the lamp will stay on when t...

Page 8: ...ll increase the flash by another one stop approximately double the light Mid way positions can be used for increases in light of less than one stop the control has small click indents to aid fractiona...

Page 9: ...be flashed Do not try to fire the unit before this indicator is lit When firing the unit at short intervals refer to the maximum advisable flash rate firing the unit too quickly can cause the flash tu...

Page 10: ...3AL For convenience all flash units are provided with a spare fuse built into the fuse holder The following procedure must be taken to replace the fuse 11 Fuse Replacement The fuse holder is accessed...

Page 11: ...amp Modes Full Prop Off Full Prop Off Auto Dump Yes Yes Colour Temperature 5300 5600k 5300 5600k Slave Cell Yes 10 metres Yes 10 metres Triggering Methods Sync Test Slave Sync Test Slave Main Operatin...

Reviews: