14
Settings
Advanced settings
Sensors &
Application
Internal Air Sensor
Offset
+/– 10°
Probe 1 Connected
On/Off
Type
5, 10, 15, 100K
Offset
+/– 10°
The STRATA_HEAT Smart LCD Thermostat uses a 10K
sensor. However, if using a STRATA_HEAT Smart LCD
Thermostat to replace an existing thermostat you must
change to the correct sensor type.
Probe 2 Connected
On/Off
Type
5, 10, 15, 100K
Offset
+/– 10°
Swap Probe Usage
The function of Probe 1, Probe 2 from Control/ Limit
Sensor can be swapped here.
Floor thermostat
(Probe 1 On, Probe 2
Off. See Table 1.0 for
alternative thermostat
use cases)
Control
Floor
Remote Air
Regulator
Limit
None/Air
Choose to switch the method of control for the sensor; floor
sensor, remote air sensor if not installed underneath the
floor or regulator mode.
Regulator Mode; Heating is on for X% out of control cycle
(default 10 mins). Heating is off for remaining time.
Floor type*
Tile/Stone
Laminate
Carpet
Wood
Vinyl
Other
Choose the floor type of your installation. This will
apply different temperature and overheat limits to the
STRATA_HEAT Smart LCD Thermostat.
* Not applicable if conventional heating system
was selected.
Display, cont’d
Night period
Set the
Start
and
End
period
This is the time when you usually go to bed at night and wake up in the morning.
The brightness of “Night” mode will begin and end using this time.
Screen lock
On/Off
Locks the STRATA_HEAT
™
Smart LCD Thermostat screen to prevent any unauthorised
changes to the STRATA_HEAT Smart LCD Thermostat. Requires a 4 digit code to
access the menu or make changes.
Advanced Settings