Advanced settings

Sensors & 
Application

Internal Air Sensor

Offset

+/– 10°

Probe 1 Connected

On/Off
Type

5, 10, 15, 100K

Offset

+/– 10°

The STRATA_HEAT Smart LCD Thermostat uses a 10K 

sensor. However, if using a STRATA_HEAT Smart LCD 

Thermostat to replace an existing thermostat you must 

change to the correct sensor type.

Probe 2 Connected

On/Off
Type 

5, 10, 15, 100K 

Offset

 

+/– 10°

Swap Probe Usage

The function of Probe 1, Probe 2 from Control/ Limit 

Sensor can be swapped here.

Floor thermostat 

(Probe 1 On, Probe 2 

Off. See Table 1.0 for 

alternative thermostat 

use cases)

Control 

Floor 
Remote Air 
Regulator 

Limit

 

None/Air

Choose to switch the method of control for the sensor; floor 

sensor, remote air sensor if not installed underneath the 

floor or regulator mode.
Regulator Mode; Heating is on for X% out of control cycle 

(default 10 mins). Heating is off for remaining time.

Floor type*

Tile/Stone 

Laminate 

Carpet 

Wood 

Vinyl 

Other

Choose the floor type of your installation. This will 

apply different temperature and overheat limits to the 

STRATA_HEAT Smart LCD Thermostat. 

* Not applicable if conventional heating system 

was selected.

Display, cont’d

Night period

Set the 

Start

 

and 

End

 period

This is the time when you usually go to bed at night and wake up in the morning. 

The brightness of “Night” mode will begin and end using this time.

Screen lock

On/Off

Locks the STRATA_HEAT

 Smart LCD Thermostat screen to prevent any unauthorised 

changes to the STRATA_HEAT Smart LCD Thermostat. Requires a 4 digit code to 

access the menu or make changes.

Advanced Settings

Summary of Contents for STRATA HEAT

Page 1: ...Smart LCD Thermostat Operating Manual Wi Fi...

Page 2: ...the STRATA_HEAT Smart LCD Thermostat 8 Getting Started 8 How to quickly change the temperature 8 How to quickly change mode 8 Heating 9 How to set a program 9 Setback Temperature 9 How to set into Ma...

Page 3: ...indoor use only It must not be exposed to moisture vibrations mechanical loads or temperatures outside of its rated values q For safety and licensing reasons unauthorised change and or modification o...

Page 4: ...ax 15A 1800W 120V 3600W 240V LINE L1 Supply Live 120 V LINE L2 Supply Neutral 120 V Supply Live 240 V P1 PC Probe 1 Floor Air Control Sensor No Polarity Floor or air temperature reading for scheduled...

Page 5: ...OUT of room Floor temperature schedule Floor limit P1 PC Floor Sensor P2 PC Floor Limit 7 Thermostat OUT of room Air temperature schedule Floor limit P1 PC Air Sensor P2 PC Floor Limit 8 Thermostat I...

Page 6: ...g loads connect to Relay 25 N B and STRATA_HEAT Smart LCD Thermostat Relay 25 Max load 25A Thermostat Max load 15A Total Max load 40A Snubber contact suppressor Heating Load connected to Relay 25 Max...

Page 7: ...p your house location and then the room within which your new STRATA_HEAT Smart LCD Thermostat is located Location A location needs to be setup before a room can be configured and the STRATA_HEAT Smar...

Page 8: ...slider or press the icons to set a temporary override until next heating period Target Temperature Temperature you wish the thermostat to achieve Weather 7 day forecast for your area Menu Air Floor l...

Page 9: ...ppy press Accept to save the heating schedule This will return you to the previous screen to repeat as necessary NOTE For tailor made preset heating schedules for different room types press the three...

Page 10: ...ntain this temperature until another operating mode or temperature is selected Thu 11 Mar 17 00 74 0 until 11 30 65 0 limit Floor 70 0 72 0 Back Menu Mode Program Energy Monitor Settings Mode Program...

Page 11: ...reen or going into mode select and pressing the Heating Off slider Thu 11 Mar 17 00 74 0 until 11 30 65 0 limit Floor 70 0 72 0 Back Menu Mode Program Energy Monitor Settings Mode Program Manual Heati...

Page 12: ...t 24 Hours 1 5kWh 0 0kWh 0 0kWh 0 0kWh Last 7 Days Since reset Last 30 Days Back Reset record Power Settings 1 500 W Dismiss Accept 1 2 3 4 5 6 7 8 0 9 How Energy Monitor works Changing the Power Sett...

Page 13: ...k Wi Fi Connection On Off It is possible to set a new Wi Fi connection from here The current network connection can also be viewed from this menu including the signal strength Display Background Light...

Page 14: ...sensor remote air sensor if not installed underneath the floor or regulator mode Regulator Mode Heating is on for X out of control cycle default 10 mins Heating is off for remaining time Floor type T...

Page 15: ...at is in the room to be heated then it can be set into Air Mode To set into Air Mode go to Sensors Application in Advanced Settings and switch the probe off Heating is coming on earlier than programme...

Page 16: ...ermostat connect to your Wi Fi Network Set up a mobile hotspot using a smartphone On a separate device login to the MySTRATA_HEAT app Try to connect the STRATA_HEAT Smart LCD Thermostat to this mobile...

Page 17: ...ion degree 2 Max Ambient Temperature 40 C 104 F T40 Relative Humidity 80 IP Rating IP30 Sensors Floor Air Sensor Type NTC10K 25 C Operating Frequency 2401 2484MHz Max Radio Frequency Power Transmitted...

Page 18: ...shall not apply if it is shown by LATICRETE that the defect or malfunction was caused by failure to follow the instruction manuals incorrect installation or damage which occurred while the product was...

Page 19: ...ETE International Inc All trademarks shown are the intellectual properties of their respective owners LATICRETE International Inc One LATICRETE Park North Bethany CT 06524 3423 USA 1 800 243 4788 1 20...

Reviews: