background image

3

13

14

11

12

Attach a butt crimp to either end of the 

ground braid using a crimping tool.

Slide the small heat shrink pieces over the 

butt crimps so that the entire crimp is  

covered. Use a heat gun in order to activate 

the heat shrink.

Slide the large pieces of heat shrink over the 

small heat shrink and apply the heat gun. 

Allow the new joints to cool. Test resistance of 

the heater and then tile as normal.

Slide one small piece of heat shrink over both 

sections of exposed ground braid. Cut a section 

of the “bridge” wire provided to a length 

suitable to replace the wire removed from the 

heating element. Strip 0.4 in. (10 mm) from 

either end of this wire into the butt crimps 

located on the ends of the ground braid and 

crimp using the crimping tool.

Slide the small heat shrink pieces over the 

butt crimps so that any bare metal is covered. 

Use a heat gun in order to activate the heat 

shrink.

9

10

Cut a section of the “bridge” wire provided to 

a length suitable to replace the wire removed 

from the heating elements. Strip 0.4 in.  

(10 mm) from either end of this wire and 

fit these ends into the butt crimps located 

on the ends of the core wire and crimp using 

the crimping tool. Test the resistance of the 

heater.

Summary of Contents for STRATA_HEAT 120V

Page 1: ...sistance 0802 0083 4 177 2 0802 0100 4 147 7 0802 0133 4 109 7 0802 0166 4 87 9 0802 0200 4 73 4 0802 0233 4 62 6 0802 0266 4 54 9 0802 0299 4 48 8 0802 0332 4 44 0 0802 0415 4 35 1 0802 0498 4 29 2 0...

Page 2: ...t Slide one piece of the large black heat shrink over one end of the wire Attach a butt crimp to either end of the heater cores using a crimping tool Slide one piece of the small heat shrink over each...

Page 3: ...f the bridge wire provided to a length suitable to replace the wire removed from the heating element Strip 0 4 in 10 mm from either end of this wire into the butt crimps located on the ends of the gro...

Page 4: ...wn are the intellectual properties of their respective owners LATICRETE International Inc l One LATICRETE Park North Bethany CT 06524 3423 USA l 1 800 243 4788 l 1 203 393 0010 l www laticrete com For...

Page 5: ...0233 2 15 6 0802 0266 2 13 7 0802 0299 2 12 2 0802 0332 2 11 0 0802 0365 2 10 0 0802 0398 2 9 1 240V Mod le R sistance 0802 0083 4 177 2 0802 0100 4 147 7 0802 0133 4 109 7 0802 0166 4 87 9 0802 0200...

Page 6: ...dissipateur de chaleur noir sur une extr mit du fil Fixez un embout de sertissage aux deux extr mit s des c urs du dispositif de chauffage l aide d un outil de sertissage Glissez un morceau du petit...

Page 7: ...pos e Coupez une section du fil pont fourni une longueur ad quate pour remplacer le fil enlev de l l ment de chauffage D nudez 10 mm 0 4 po de chaque extr mit de ce fil et ins rez ces extr mit s dans...

Page 8: ...sont la propri t intellectuelle de leurs propri taires respectifs LATICRETE International Inc l One LATICRETE Park North Bethany CT 06524 3423 USA l 1 800 243 4788 l 1 203 393 0010 l www laticrete co...

Page 9: ...2 0266 2 13 7 0802 0299 2 12 2 0802 0332 2 11 0 0802 0365 2 10 0 0802 0398 2 9 1 Modelo 240V Resistencia 0802 0083 4 177 2 0802 0100 4 147 7 0802 0133 4 109 7 0802 0166 4 87 9 0802 0200 4 73 4 0802 02...

Page 10: ...e cortado Deslice una pieza del termoencogible negro grande sobre un extremo del cable Fije un engarzado a tope a cualquiera de los extremos de los n cleos del calentador usando una herramienta de eng...

Page 11: ...del cable de puente a una longitud conveniente para reemplazar el cable retirado del elemento de calefacci n Quite 10 mm 0 4 pulg de cualquiera de los extremos de este cable y encaje estos extremos e...

Page 12: ...n propiedad intelectual de sus respectivos propietarios LATICRETE International Inc l One LATICRETE Park North Bethany CT 06524 3423 USA l 1 800 243 4788 l 1 203 393 0010 l www laticrete com Para cual...

Reviews: