Skynode
®
S100 Installation and Operation Manual
Page
31
of
32
S100-400, R2.01
TABLE C1 – ENVIRONMENTAL TESTS TABLE
NOMENCLATURE: SKYNODE S100
______
TYPE/MODEL/PART NO: S100-001
TSO NUMBER: N/A
MANUFACTURER’S SPECIFICATION AND/OR OTHER APPLICABLE SPECIFICATION: N/A
MANUFACTURER: LATITUDE TECHNOLOGIES CORPORATION
ADDRESS: 101-3375 Whittier Ave
Victoria, BC, Canada, V8Z-3R1
REVISION & CHANGE NUMBER OF DO-160E: DATES TESTED: February-March 2007 and July 2010
Condition
Section
Description of tests conducted
Temperature and Altitude
Low Temperature
Ground Survival Low Temperature
Short Time Low Temperature
High Temperature
Ground Survival High Temperature
Short Time High Temperature
Altitude
Decompression
Overpressure
4.0
4.5.2
4.5.1
4.5.1
4.5.4
4.5.3
4.5.3
4.6.1
4.6.2
4.6.3
Equipment tested to Categories A4
Operating: -40
o
C
Non-Operating: -55
o
C
Operating: -40
o
C
Operating: +60
o
C
Short time high temperature: +85
o
C
Operating: +60
o
C
50,000 feet
8000 feet to 50000 feet
-15000 feet
Temperature Variation
5.0
Equipment tested to Category B
+/- 5
o
C/min.
Humidity
6.0
Equipment tested to Category A
95% RH for 48 Hours
Operational Shock and Crash Safety
Operational Shock
Crash Safety
7.0
7.2.1
7.3.1
Equipment tested to Category B
6 G for 11ms in all axes
20 G for 11ms in all axes
Vibration
8.0
8.5.1
8.8.3
Equipment tested to Categories SM and U2FF1
Sinusoidal:
0.1” from 5 to 15 Hz
0.01” from 15 to 55 Hz
1.5G from 55 to 500 Hz
Unknown Helicopter Frequencies
Vibration Profile F- Random
Vibration Profile F1-Random
Explosion
9.0
Equipment identified as Category X, no test
performed
Waterproofness
10.0
Equipment identified as Category X, no test
performed
Fluids Susceptibility
11.0
Equipment identified as Category X, no test
performed
Sand and Dust
12.0
Equipment identified as Category X, no test
performed
Fungus
13.0
Equipment identified as Category X, no test
performed
Salt Spray
14.0
Equipment identified as Category X, no test
performed
Magnetic Effect
15.0
Equipment tested to Category Z