Technical data
50
Standard settings of control parameters and pump
➾
Section 6.4.5.1. and 6.4.5.2. and 6.4.2.
Unit Type
Xp (°C)
Tn (s)
Pump outflow step
RE 104, RE 204
7,0
20
2
RE 106, RE 206, RE 306
4,0
20
2
RE 107, RE 207, RE 307
3,0
25
3
RE 112, RE 212, RE 312
4,5
30
4
RE 120, RE 220, RE 320
2,0
25
5
Pump characteristics
measured with water
0
0,05
0,1
0,15
0,2
0,25
0,3
0,35
0,4
0,45
0
2
4
6
8
10
12
14
16
18
l/min
bar
step 5
step 4
step 3
step 2
step 1