In case the alarm function as described in 7.12.3 was chosen:
The acoustic signal with dual-tone sounds.
The red LED
above the fault triangle
flashes.
Heater switches off on both poles,
Pump and refrigerating unit are switched off electronically.
Find the cause of the fault. Possible causes may be:
1. Volume expansion on heating.
2. Feed to an external vessel may be interrupted so that only
return suction is possible.
3. Heat transfer liquid taking up moisture.
If Alarm: Press Enter key. Warnings disappear automatically when
the cause is gone.
Also, press this key if the unit has been switched off in the fault
state. Warnings disappear automatically when the cause is gone.
Command
High-level warning/alarm
The display shows
Warning. To release press Enter key
Security 3 Level too high
or
Alarm AL 6: Level too high is shown in the display and
signifies that unlocking is only possible on the Master control panel.
7.12.5
Pump-motor supervision: Overload or blockage
The SelfCheck Assistant monitors the Varioflex pump:
1. Alarm sounds as dual-tone signal for pump-motor overload or
blockage.
2. Display of
bL0C
signals blockage.
3. The red LED
above the fault triangle
flashes.
Heater switches off on both poles,
Pump and refrigerating unit are switched off electronically.
Find the cause of the fault. Perhaps the viscosity of the heat
transfer liquid is too high or the pump is blocked.
Press the Enter key.
Also press this key if the unit has been switched off in the fault
state.
Command
Pump-motor alarm!
Pump-motor alarm is shown in the display and signifies that
unlocking is only possible on the Master control panel.
Pump alarm
bL0C
°C
Level alarm
AL 6
°C
Summary of Contents for RP 3050 C
Page 1: ...2SHUDWLQJ LQVWUXFWLRQV 352 1 U RPDWV RZ WHPSHUDWXUH 7KHUPRVWDWV 53 53 53 53 53 53 53 53 ...
Page 2: ......
Page 4: ......
Page 40: ...Proline Kryomats 40 Starting up YAUE0007 10 2 2018 7 Starting up ...
Page 41: ...Proline Kryomats YAUE0007 10 2 2018 Starting up 41 ...
Page 132: ...Proline Kryomats 132 YAUE0007 10 2 2018 ...
Page 134: ......
Page 135: ......