Rev. 4.00 December 2014
Software version 1.04
Part 1 • Page 14-8
Menu selection
Part 1 – Operating Instructions
EcoRO Dia I/II (HT)
Part 1 • Chap
ter 14
14.8 Passwords, menu item 8
14.9 Date time, menu item 9
14.10 System type, menu item 10
In addition to the factory-set password “2232” (password 1) for
changing the set process parameters, it is possible to save and change
a operator-specific password.
Enter password 1
Delete password 1
Enter password 2
Delete password 2
<<
OK
The date and time can be changed and updated in menu item 9. The
arrow keys can be used to change the numerical values. When a date
or time is complete, use the “<<” key to exit the menu. The entries are
stored!
Date
Time
<<
OK
NOTICE
Standard and daylight saving times are not automatically recognized or updated!
Depending on the pipes and electronic components fitted, this is a
EcoRO Dia I:
Single stage reverse osmosis system with
impulse back washing.
EcoRO Dia I HT:
Single stage reverse osmosis system with
impulse back washing and membranes for
hot cleaning.
EcoRO Dia II:
Double-stage reverse osmosis system with
impulse back washing system.
EcoRO Dia II HT:
Double-stage reverse osmosis system with
impulse back washing and membranes for
hot cleaning.
The correct setting has already been made at the factory, it is only
changed on site only if the equipment is changed!
2 Prm dialysis mode
A) Display
B) Entry
<<
ENTER
EcoRO Dia II HT
<<
OK
10 Choose system
A) Display
B) Entry
<<
ENTER
Type of system
Software version
Software language
<<
ENTER
Type of system
EcoRO Dia II
<<
+ -