Technical data
Part 2 • Page 7-13
Part 2 – Supplementary Operating Instructions
Rev. 4.00 December 2014
Software version 1.04
EcoRO Dia I/II (HT)
Part 2 • Chapt
er 7
TISAH2
(NTC)
Disinfect
K1106
Dialysis
K1103
Hard water
monitor
K1104
Standby
mode
D02
Alarm*
K1105
Lamp
dialysis
D01
Standby
Rinsing
lamp
D03
Emergency
mode lamp
D04*
Alarm
lamp
D05*
Condition / Remarks
0
0
0
0
0
0
1
0
0
0
0
inactive
0
1
1
0
0
1
0
0
0
0
Until level drops below LS1
inactive
0
1
1
0
0
1
0
0
0
0
See 6.10.7 Pos. 7.1 LS1 or LS2 exceeded
inactive
0
1
0
0
0
1
0
0
0
0
Conductivity evaluation and NTC delayed 2 min. Acc. to chap. 6.10.2 for pressure build-up line 5 or 7
inactive
0
1
1
0
0
1
0
1
0
0
See 6.10.2 menu 2.6 after elapsing of pressure to flush (line 6)
inactive
0
1
1
0
0
1
0
1
0
0
See 6.10.2 menu 2.7 after elapsing of flush back to operation (line 4)
inactive
0
1
1
0
0
1
0
1
0
0
See 6.10.2 menu 2.3 after elapsing of pressure to flush (line 8)
inactive
0
1
1
0
0
1
0
1
0
0
See 6.10.2 menu 2.4 after elapsing of flush back to operation (line 4)
inactive
0
1
1
0
0
1
0
0
0
0
Until WCF ACTUAL = WCF SETPOINT
inactive
0
1
1
0
0
1
0
0
0
0
According to menu 2.16
inactive
0
1
1
0
1
1
0
0
1
1
Motor prot. switch 3 and/or 4 failed, conductivity evaluation and NTC delayed 2 min. No IRS in emergency mode
inactive
0
1
1
0
1
1
0
0
1
1
Every minute until WCF ACTUAL = WCF SETPOINT
inactive
0
1
1
0
1
1
0
0
1
1
Motor protection switch 1 and/or 2 failed. Conductivity evaluation and NTC delayed by 2 min.
No IRS in emergency mode.
inactive
0
0
0
1
0
0
1
0
0
0
Until level drops below LS1. Continue at line 15
inactive
0
0
0
1
0
0
1
0
0
0
Fill up to LS1, wait according to menu 4.9, then continue at line 16
inactive
0
0
0
1
0
0
1
0
0
0
Fill up to LS2, then continue at line 17
inactive
0
0
1
1
0
0
1
1
0
0
M3 on when 6.10.4 menu 4.5 = 1. Duration according menu 4-3, after elapsing go to line 21,
Y30 on according menu 4.10/4.11/4.12. Leakage monitoring on, Conductivity monitoring off.
inactive
0
0
1
1
0
0
1
1
0
0
See 6.9.2 after elapsing, back to line 17
inactive
0
0
1
1
0
0
1
1
0
0
Only EcoRO Dia and menu 4.6 = on, then swell according menu 2.4, after exceeding go to line 17.
inactive
0
0
1
1
0
0
1
0
0
0
Start if menu 4.4 = on and start valuation XX° C has been reached.
Stop temperature discharge if stop valuation XX°C has been reached. If DI 06 = 0 program termination intermediate
rinsing and switch into break. If Y9 = 1 and LSHL2 > 5 sec. = 0, close Y9 until LSHL2 = 1 and then open Y9 again.
inactive
0
0
0
1
0
0
1
0
0
0
Time-controlled: 6.10.4: 4.1 + 4.2
inactive
0
0
1
1
0
0
1
0
0
0
Menu 4.2 + 4.3 = 0 minutes of leakage monitoring
inactive
1
0
0
0
1
0
0
0
0
1
Until LS1 is exceeded, after this line 24
inactive
1
0
0
0
1
0
0
0
0
1
Continue via keyboard
inactive
Until LS2 is exceeded
inactive
1
0
0
0
1
0
0
0
0
1
Conductivity control permeate, Display remaining time, When conductivity > 98µS/cm after 20 min go to line 31.
Duration according chater 6.10.5, after this line 31
inactive
1
0
0
0
1
0
0
1
0
1
During circulation operation + 1 minute, after this go to line 28
inactive
1
0
0
0
1
0
0
1
0
1
After finishing + 30 seconds go to line 29
inactive
1
0
0
0
1
0
0
1
0
1
After this line 30
inactive
1
0
0
0
1
0
0
1
0
1
After this go back to line 26
inactive
1
0
0
0
1
0
0
0
0
1
Display remaining time, Duration: 6.10.5: Menu 5.3 After this go to line 32.
inactive
1
0
0
0
1
0
0
0
0
1
Until LS2 is exceeded
inactive
1
0
0
0
1
0
0
0
0
1
When LS1 drops below back to filling tank
15 minutes before the end: Message: check disinfectant residue. If conductivity > +25% after disinfection, back to start
line 32. Keyboard back to rinsing operation or end of disinfection. End = back to basic state standby operation or off.
If LS2 exceeds IRS1 or IRS2 alternately.
inactive
1
0
0
0
1
0
0
1
0
1
After completion menu 2.7, continue with “empty tank” line 33
inactive
1
0
0
0
1
0
0
1
0
1
After completion menu 2.4, continue with “empty tank” line 33
inactive
1
0
0
0
1
0
0
0
0
1
Until LS1 is exceeded, then line 37
inactive
1
0
0
0
1
0
0
0
0
1
Continue via keyboard
inactive
0
Until LS2 is exceeded
inactive
1
0
0
0
1
0
0
0
0
1
Display remaining time, Duration according chapter 6.10.6 menu 6.2; then line 44
inactive
1
0
0
0
1
0
0
1
0
1
During circulation operation +1 min, continue with line 41
inactive
1
0
0
0
1
0
0
1
0
1
After completion + 30 sec: then line 42
inactive
1
0
0
0
1
0
0
1
0
1
Then line 43
inactive
1
0
0
0
1
0
0
1
0
1
Then back to line 39
inactive
1
0
0
0
1
0
0
0
0
1
Display remaining time: 6.10.6 menu 6.3. Continue with line 45
inactive
1
0
0
0
1
0
0
0
0
1
Until LS2 is exceeded
inactive
1
0
0
0
1
0
0
0
0
1
If level drops below LS1 back to filling tank.
15min. before end: Message: check cleaning residue. With keyboard back to rinsing operation or end cleaning.
End = back to basic state standby operation or off. If LS2 is exceeded IRS1 or IRS2 alternating.
inactive
1
0
0
0
1
0
0
1
0
1
After completion menu 2.7, continue with “empty tank” line 46
inactive
1
0
0
0
1
0
0
1
0
1
After completion menu 2.4, continue with “empty tank” line 46
active
1
0
0
1
0
0
1
0
0
0
• Heat up until temp. in menu 12.2 has been reached
• #3 = close Y90 if
Δ
T
≥
2°K/min., open
Δ
T
≤
+2°K/min.
active
1
0
0
1
0
0
1
0
0
0
• #3 = close Y90 if
Δ
T
≥
2°K/min., open
Δ
T
≤
+2°K/min.
• Duration according to menu 12.4 or menu 12.5
• After end of period change to cool down phase
active
1
0
0
1
0
0
1
0
0
0
• #14 = close Y8 if
Δ
T
≥
2°K/min., open
Δ
T
≤
+2°K/min.
• #15 = if temperatur menu 12.2 has been reached, close Y5, Y5.1 and Y8
• if temperature menu 12.2 has been reached, back to line 21 “Standby operation break”
active
1
0
0
1
0
0
1
0
0
0
• #14 = close Y8 if
Δ
T
≥
2°K/min., open
Δ
T
≤
+2°K/min.
• #15 = if temperature menu 12.2 has been reached, close Y5, Y5.1 and Y8
active
#10
1
1
0
0
1
0
0
0
0
• #10 = As long as signal HWD1 is pending, Y5.1.1 off and K1106 disinfection on, when signal HWD1 is no longer
pending, Y5.1.1 on and K1106 disinfection off.
• #14 = close Y8 if
Δ
T
≥
2°K/min., open if
Δ
T
≤
+2°K/min.
• #15 = If temperature menu 12.2 has been reached, close Y5, Y5.1 and Y8
active
1
0
0
1
0
0
1
0
0
0
• Heat up until temp. in menu 12.3 has been reached
• #2 = close Y5.1.1 if
Δ
T
≥
2°K/min.,open if
Δ
T
≤
+2°K/min.
• #4 = open Y30 for 1 sec. every 120 seconds, open Y3 for 2 sec. when Y30 is closed again, open Y6 for 2 sec. when
Y3 is closed again, open Y7 for 2 sec. and at the same time M3 on when Y6 is closed again and when Y7 is open
close Y8
active
1
0
0
1
0
0
1
0
0
0
• #2 = close Y5.1.1 if
Δ
T
≥
2°K/min., open if
Δ
T
≤
+2°K/min.
• #4 = open Y30 for 1 sec. every 120 seconds, when Y30 is closed again open Y3 for 2 sec., when Y3 is closed again
open Y6 for 2 sec., when Y6 is closed again open Y7 for 2 sec. and at the same time M3 on, when Y7 is open close Y8
active
1
0
0
1
0
0
1
0
0
0
• #14 = close Y8 if
Δ
T
≥
2°K/min., open if
Δ
T
≤
+2°K/min.
• #11 = close Y9 if
Δ
T
≥
2°K/min., open if
Δ
T
≤
+2°K/min.
• If temperature menu 12.3has been reached, back to line 21 “Standby operation break”
active
1
0
0
1
0
0
1
0
0
0
• #14 = close Y8 if
Δ
T
≥
2°K/min., open if
Δ
T
≤
+2°K/min.
• #11 = close Y9 if
Δ
T
≥
2°K/min., open if
Δ
T
≤
+2°K/min.
active
#10
1
1
0
0
1
0
0
0
0
• #10 = As long as signal HWD1 is pending, Y5.1.1 off and K1106 disinfection on, when signal HWD1 is no longer
pending Y5.1.1 on and K1106 disinfection off.
• #11 =close Y9 if
Δ
T
≥
2°K/min., open if
Δ
T
≤
+2°K/min.
• #14 = close Y8 if
Δ
T
≥
2°K/min., open if
Δ
T
≤
+2°K/min.
active
1
0
0
1
0
0
1
0
0
0
• Heat up until temp. menu 12.4 is reached
• #2 = close Y5.1.1 when
Δ
T
≥
2°K/min., open when
Δ
T
≤
+2°K/min.
• #16 = open Y30 every 120 seconds for 1 sec, when Y30 closed again, open Y3 for 2 sec, when Y3 closed again,
open Y6 for 2 sec.
active
1
0
0
1
0
0
1
0
0
0
• #2 = close Y5.1.1 when
Δ
T
≥
2°K/min., open when
Δ
T
≤
+2°K/min.
• #16 = open Y30 every 120 seconds for 1 sec, when Y30 closed again, open Y3 for 2 sec, when Y3 closed again,
open Y6 for 2 sec.
active
1
0
0
1
0
0
1
0
0
0
• #11 = close Y9 when
Δ
T
≥
2°K/min., open when
Δ
T
≤
+2°K/min.
• Actual temperature menu 12.4 reached, back to line 21 “Standby mode break”
active
1
0
0
1
0
0
1
0
0
0
• #11 = close 9 if
Δ
T
≥
2°K/min., open if
Δ
T
≤
+2°K/min.
active
#10
1
1
0
0
1
0
0
0
0
• #10 = as long as signal HWD1 is pending, Y5.1.1 off and K1106 disinfection on, when signal HWD1 is no longer
pending, Y5.1.1 off and K1106 disinfection off.