7.7 EPC PM 1900t/1900 Nautic Front 

View

230±0.1

Power On-Off

483.2±0.1

465.2±0.1

235±0.1

1 x USB waterproof

104.5±0.1

444±0.1

8 x boreholes Ø 6.5

R10.0

Brightness Down

Brightness Up

Summary of Contents for EPC PM 1500

Page 1: ...EPC PM Nautic Installation Manual MAEN971 2009 01 English ...

Page 2: ...tion manual prior to installing and using this equipment Only qualified personnel may install operate or repair this equipment Elektronik Systeme Lauer GmbH Co KG is not responsible for modified altered or renovated equipment Because the equipment has a wide range of applications users must acquire the appropriate knowledge to use the equipment properly in their specific applications Persons respo...

Page 3: ...of Parts 10 3 1 EPC PM Nautic 10 3 2 Display 11 3 3 Communication Ports 230 V AC 12 3 4 Communication Ports 24 V DC 12 3 5 Configuration of COM4 13 3 6 Motherboard 14 3 7 Assembly 14 3 8 Power Supply 15 3 9 Earthing System 16 3 10 ATX Power Switch 16 4 Operation 17 4 1 Operating System 17 4 2 BIOS Settings 18 4 3 Important Items Regarding Software Installation 19 4 4 Touch Screen Installation 20 4...

Page 4: ... 1500t 1500 Nautic Cut Out Drawing 42 7 3 EPC PM 1500t 1500 Nautic Outline Drawings 43 7 4 EPC PM 1700t 1700 Nautic Front View 44 7 5 EPC PM 1700t 1700 Nautic Cut Out Drawing 45 7 6 EPC PM 1700t 1700 Nautic Outline Drawings 46 7 7 EPC PM 1900t 1900 Nautic Front View 47 7 8 EPC PM 1900t 1900 Nautic Cut Out Drawing 48 7 9 EPC PM 1900t 1900 Nautic Outline Drawings 49 7 10 EPC PM 2100t 2100 Nautic Fro...

Page 5: ... DNV ABS RS CCS KR EN 60945 EPC PM 1500t 1500 Nautic X X X X X X EPC PM 1700t 1700 Nautic X X X X X X X X X X EPC PM 1900t 1900 Nautic X X X X X X X X X X EPC PM 2100t 2100 Nautic X X X X X X X X X X In progress For bridge applications Approval Certificate Abbreviation Conformité Européene CE Lloyd s Register LR Bureau Veritas BV Germanischer Lloyd GL Det Norske Veritas DNV American Bureau of Ship...

Page 6: ...the EPC This may cause fire or electrical shock Only qualified personnel may operate the EPC Storing the EPC where the temperature is lower higher than recommended in this manual can cause the LCD display liquid to congeal become isotopic The LCD display liquid contains a powerful irritant In case of skin contact wash immediately with plenty of water In case of eye contact hold the eye open flush ...

Page 7: ...rding to the accompanying installation instructions Only qualified personnel may install the EPC Separate the high voltage signal and supply cables Make sure that the voltage and polarity of the power source is correct before connecting the EPC to the power outlet Peripheral equipment must be appropriate for the application and location The controlling transformer has to comply with EN60742 1 4 Du...

Page 8: ...ctrical supply Clean the display and surrounding front cover with a soft cloth and mild de tergent Replacing the battery incorrectly may result in explosion Only use batteries recommended by the supplier 1 6 Dismantling and Scrapping The EPC or parts thereof shall be recycled according to local regulations The following components contain substances that might be hazardous to health and the enviro...

Page 9: ...ower cable Standard power cable European or US standard for units with 230 V AC power supply Length approximately 3 0 m 24 V DC units are delivered without cable Installation manual This manual describes specific information about Elektronik Systeme Lauer products only not about third party components Note Separate documentation of third party components is included on the enclosed driver software...

Page 10: ... 10 Elektronik Systeme Lauer MAEN971 3 Description of Parts 3 1 EPC PM Nautic The EPC PM Nautic consists of a Front Unit and a PC Unit These are installed in the same way independent of the display size Front unit PC unit ...

Page 11: ...the monitor off Press the power button again Turns the monitor on Press brightness down on the dimmer button Makes the display darker Press brightness up on the dimmer button Makes the display brighter Keep the power button pressed and at the same time press brightness down on the dimmer button Auto configuration of the monitor Press the power button and keep it pressed and at the same time press ...

Page 12: ... USB 1 USB 2 0 LAN 2 RJ 45 USB 4 USB 2 0 USB 3 USB 2 0 and fuse terminal LPT 1 DB25F PCI slot 1 PCI slot 2 mini jack Power remote screw terminal Power screw Power remote PS 2 Mouse Keyboard COM1 DB9M COM2 DB9M VGA DB15HDF COM4 DB9M Compact Flash Audio 3 x 3 5 mm LAN 1 RJ 45 USB 2 USB 2 0 USB 1 USB 2 0 LAN 2 RJ 45 USB 4 USB 2 0 USB 3 USB 2 0 terminal LPT 1 DB25F PCI slot 1 PCI slot 2 mini jack Fuse...

Page 13: ...d as RS485 or AUX using jumpers When configured as RS485 the pins are assigned at half duplex according to be low Jumper positions Description 1 3 2 4 7 9 8 10 On RS232 default setting 3 5 4 6 7 9 8 10 On RS485 9 11 12 V 10 12 5 V On Auxiliary power Pin number Description Pin 1 RX TX Pin 2 RX TX Pin 5 Ground Pin 9 optional 5 V auxiliary power supply 12 11 2 1 ...

Page 14: ...in the supplied mounting kit Note The quality of the memory module may influence the system stability When updating the memory module or adding a second one please only use memory modules cleared by Elektronik Systeme Lauer Memory modules are electrostatic sensitive components Relevant protective measures earth have to be considered during as sembly disassembly ESD protective measures are to be co...

Page 15: ...is carried out via a double pole connector Phoe nix MST BT 2 5 2 The EPC PM Nautic is certified for the connection to protective grounded power supply according to EN60950 The controlling transformer has to com ply with EN60742 Note Check the power supply system with the relevant data on the type plate Earth screw Supply connection 230 V AC Earth screw Supply connection 24 V DC Fuse 6 3 A ...

Page 16: ...done in accordance with ATX specification via the ATX power switch the red button next to the power supply Should a correct automatic booting not function then this can have the follow ing reason In the BIOS settings the option PWRON After PWR Fail in the Integrated Peripherals Super IO Device menu must be enabled i e On See also section 4 2 BIOS Settings The operating system must be ended correct...

Page 17: ...ilingual C and D NTFS The operating system and other programs installed on drive C while drive D is a complete free partition which for example can be used for your data beneficial for example for data back up Drive E contains all data required for a new installation drivers and operation system This partition always uses a FAT 16 data system ...

Page 18: ...MOS Features Time Current time Standard CMOS Features Check that all IDE Devices HD CD and CF are cor rectly recognized Advanced BIOS Features First Boot Device HDD 1 Advanced BIOS Features Second Boot Device HDD 0 Advanced BIOS Features Third Boot Device Disabled Advanced BIOS Features Boot Other Device Disabled Advanced BIOS Features Boot up Floppy Seek Disabled Advanced Chipset Features Panel N...

Page 19: ... formation and therefore no improvement is achieved from a higher setting Install the touch screen drivers in accordance with the instructions Note Higher settings can even seriously damage the graphic board display Note To avoid always having to re start the installation procedure of the operating sys tem we recommend making an image of the new hard disk using e g Norton Ghost Drive Image etc The...

Page 20: ...ch Screen Installation Technical data check the BIOS settings when re installing Serial Tsharc 12 Touch Controller Com 3 check the BIOS settings 3E8 hex IRQ 4 9600 bps Perform the SETUP EXE under E Driver Driver EPC PM Touch Touch CD ROM D E EPC PM Touch ...

Page 21: ...Operation Elektronik Systeme Lauer MAEN971 21 1 Follow the instructions on the screen and press Continue 2 Accept the license provisions ...

Page 22: ...Operation 22 Elektronik Systeme Lauer MAEN971 3 Select Autodetect or manually select the technical connection data ...

Page 23: ... 23 4 Press Finish and follow the instructions for a re start 5 After a re start of the operating system you will find Hampshire Control Panel among the programs 6 Calibrate the touch screen with your finger or with a rounded pointed touch pen ...

Page 24: ...matic driver search of the graphic board driver The graphic driver is located on the delivered Driver CD or on partition E EPC PM Grafic 1 Run Setup exe from the Utilities directory 2 After finishing the installation and re starting the EPC PM Nautic the fol lowing entries are available under the Display icon in the Control Panel or in the display properties Note The grafic driver will be installe...

Page 25: ...e second network card open the EXE file from the drive directo ry Drive E Driver EPC PM LAN Confirm each installation step and re start the EPC PM Nautic at the end of the installation After the re start two new network icons appear in the right hand side lower task bar You can now configure both network cards to your own requirements IP address etc via the system control Via the MS DOS window und...

Page 26: ...Operation 26 Elektronik Systeme Lauer MAEN971 ...

Page 27: ...carried out by au thorized personnel Only the expansion of hardware with memory and plug in cards is permissible within the defects liability period Attention Deadly Peril Make sure that your electrostatic pad does not damage the front panel of the EPC PM Nautic Note Inside the appliance there are electronic components which can be destroyed by electrostatic charges Therefore cautionary measures h...

Page 28: ... Changing the Fan 1 To change the fan you have to remove the left hand part of the rear enclo sure To open the enclosure remove the six 6 marked screws with an Allen key 2 Lift the enclosure and pull out the fan cable according to the picture below ...

Page 29: ...the cable prior to pulling the cable out so that the new fan can be plugged in correctly Unplug and remove the fan 4 Remove the protective cover of the fan and remove the fan with a Phillips head screw driver 5 After changing the fan assemble the appliance in the reverse order ...

Page 30: ...3 PCI board Installation To install a PCI board the right hand side part of the rear enclosure has to be removed 1 To open the enclosure remove the marked seven screws with an Allen key After removing the screws the enclosure can be easily removed ...

Page 31: ...eme Lauer MAEN971 31 The picture of the opened appliance below shows the board holder 1 and the 2 PCI slots 2 2 Remove the cover of the desired slot to insert your PCI board by removing the screw and pulling out the cover 1 2 ...

Page 32: ...ove the board holder by unscrewing the two screws marked below 4 Insert the PCI board if necessary bend the slot bracket a little bit Please ensure a correct fit at the rear edge 3 of the slot and make sure the metal bracket goes into the groove 4 3 4 ...

Page 33: ...Service Elektronik Systeme Lauer MAEN971 33 5 Mount your PCI board and make sure to properly tighten the screw 6 Re assemble the board holder and tighten the two screws properly ...

Page 34: ...ensure an optimal use of the board holder we recommend that you put wide boards in the lower slot and narrow boards in the upper This way the support can be used in the correct way Note If two wide boards are used the short support 5 can be removed 5 ...

Page 35: ... Module 1 To change or expand the memory card you have to remove the left hand part of the rear enclosure To open the enclosure remove the six 6 marked screws with an Allen key 2 Lift the enclosure and pull out the fan cable according to the picture below ...

Page 36: ...iew of the slots Pull out the ribbon cable 1 and move it to the top according to arrow 2 4 The picture above shows one free 3 and one occupied slot If a memory expansion is carried out the memory module is positioned vertically and pushed into the slot the fixing brackets 4 shall snap shut 1 2 3 4 ...

Page 37: ...ing to the below picture The memory board is now loose and can be removed 6 To mount a new memory board center it into the slot and push it firmly but gently down until the holding brackets snap shut 7 Bend back and plug in the ribbon cable 8 Subsequently plug in the fan cable and reposition the enclosure 9 Re fix the enclosure ...

Page 38: ...Service 38 Elektronik Systeme Lauer MAEN971 ...

Page 39: ...eal IP65 Rear panel seal IP20 according to DIN EN 60529 Weight 8 5 kg 10 7 kg 13 kg 18 5 kg Processor Intel Celeron M 1 3 GHz Cache PCI Clock 512 KB level 2 cache 400 MHz Bus System chipset Intel 82855GME BIOS Award 2 MBit Flash supports ACPI RAM 1024 MB DDR SDRAM max 2 GB Mass storage Hard disk 2 5 Automotive 40 GB Graphics chip Intel 82855GME Integrated 250 MHz IDE controller 1 x IDE port Ultra ...

Page 40: ...mber of colors 16 7 million View angle up down left right typical 50 60 75 75 89 Light intensity typical 250 cd m2 300 cd m2 Contrast ratio 450 1 1500 1 1000 1 Response time 6 ms 19 ms 15 ms 10 ms 13 ms 7 ms 16 ms 12 ms Display technology TN PVA SPVA Touch screen technology Resistive Touch screen resolution 4096 x 4096 points Ambient temperature 0 to 55 C Relative ambient humidity 30 to 90 non con...

Page 41: ...Drawings Elektronik Systeme Lauer MAEN971 41 7 Drawings 7 1 EPC PM 1500t 1500 Nautic Front View R5 0 394 412 Brightness Up Brightness Down 351 222 333 206 1x USB waterproof 64 5 Power On Off ...

Page 42: ...PM 1500t 1500 Nautic Cut Out Drawing Cut out dimensions 369 0 x 324 0 mm Mounting method 6 x M6x25 V2A screws DIN 6912 Screws and o ring seals are included Max 5 mm thick mounting frame 369 197 394 324 197 333 222 6 x boreholes Ø 6 5 max thickness 5 0 mm ...

Page 43: ...Drawings Elektronik Systeme Lauer MAEN971 43 7 3 EPC PM 1500t 1500 Nautic Outline Drawings Bottom view Rear view Side view 395 367 12 169 85 28 R3 0 Fan 188 5 363 336 5 104 5 87 5 144 2 0 0 0 134 41 ...

Page 44: ...Drawings 44 Elektronik Systeme Lauer MAEN971 7 4 EPC PM 1700t 1700 Nautic Front View 200 0 1 430 0 1 414 0 1 390 0 1 105 0 1 1 x USB waterproof 180 0 1 Brightness Down Brightness Up Power On Off R10 0 ...

Page 45: ... Nautic Cut Out Drawing Cut out dimensions 396 0 x 364 0 mm Mounting method 8 x M6x25 V2A screws DIN 6912 Screws and o ring seals are included Max 5 mm thick mounting frame 200 0 2 396 1 0 414 0 2 374 0 2 180 0 2 364 1 0 92 0 2 8 x boreholes Ø 6 5 max thickness 5 0 mm ...

Page 46: ...Drawings 46 Elektronik Systeme Lauer MAEN971 7 6 EPC PM 1700t 1700 Nautic Outline Drawings Bottom view Rear view Side view 395 367 12 169 85 28 R3 0 Fan 188 5 363 336 5 104 5 87 5 144 2 0 0 0 134 41 ...

Page 47: ...ktronik Systeme Lauer MAEN971 47 7 7 EPC PM 1900t 1900 Nautic Front View 230 0 1 Power On Off 483 2 0 1 465 2 0 1 235 0 1 1 x USB waterproof 104 5 0 1 444 0 1 8 x boreholes Ø 6 5 R10 0 Brightness Down Brightness Up ...

Page 48: ...Nautic Cut Out Drawing Cut out dimensions 438 x 416 mm Mounting method 8 x M6x25 V2A screws DIN 6912 Screws and o ring seals are included Max 5 mm thick mounting frame 426 0 2 230 0 2 465 2 0 2 438 1 0 234 9 0 2 90 6 0 2 416 1 0 8 x boreholes Ø 6 5 max thickness 5 0 mm ...

Page 49: ...ngs Elektronik Systeme Lauer MAEN971 49 7 9 EPC PM 1900t 1900 Nautic Outline Drawings Bottom view Rear view Side view R3 0 434 386 5 188 6 104 6 47 5 12 10 412 388 2 238 7 154 7 136 7 144 2 0 0 0 134 40 Fan ...

Page 50: ...0 Elektronik Systeme Lauer MAEN971 7 10 EPC PM 2100t 2100 Nautic Front View 223 0 1 Power On Off 534 0 1 516 0 1 313 0 1 1 x USB waterproof 105 0 1 Brightness Down Brightness Up 8 x boreholes Ø 6 5 R10 0 481 0 1 ...

Page 51: ...t 2100 Nautic Cut Out Drawing Cut out dimensions 500 x 443 mm Mounting method 8 x M6x25 V2A screws DIN 6912 Screws and o ring seals are included Max 5 mm thick mounting frame max thickness 5 0 mm 313 0 2 223 0 2 500 1 0 516 0 2 443 1 0 463 0 2 8 x boreholes Ø 6 5 ...

Page 52: ...Drawings 52 Elektronik Systeme Lauer MAEN971 7 12 EPC PM 2100t 2100 Nautic Outline Drawings Bottom view Rear view Side view 498 418 5 79 5 R3 0 441 2 415 5 164 2 134 40 144 Fan ...

Page 53: ... Tel 46 40 35 86 00 Fax 46 40 93 23 01 www beijerelectronics com info beijerelectronics com SUBSIDIARY CENTRAL EUROPE Elektronik Systeme Lauer GmbH Co KG Kelterstraße 59 72669 Unterensingen Germany Tel 49 7022 9660 0 Fax 49 7022 9660 103 www lauer hmi com info lauer hmi com ...