background image

Page 6 

User Instructions 

Universal Slider Action Solenoid S.1 

V2.0 

– HW rev. 15 – SW rev. 1.7 

 

Aug. Laukhuff GmbH & Co. KG     August-Laukhuff-Straße 1      D-97990 Weikersheim 

Telephone: +49 7934/9160-0     Fax: +49 7934/616     E-Mail: info@laukhuff.de 

www.laukhuff.de 

 

Level 1 

Level 2 

Level 3 

(standard) 

Level 4 

Level 5 

Level 6 

Level 7 

Level 8 

 

 

 

 

 

 

 

 

Lowest 
speed 

Highest 

speed 

 

Attention:

 

Remember that a higher speed also increases the magnets’ current consumption. Especially 

the highest levels 6 to 8 can dramatically increase power consumption, e.g. from 2 A on level 3 to 4 A on 
level 8.

 

 
Feature 7: DIAGNOSTICS 
 

The diagnostics function allows testing of the light barrier, input, button and RS output functions. 
 
LED 1 

 end position sensor OFF 

LED 2 

 track sensor OFF 

LED 3 

 track sensor ON 

LED 4 

 end position sensor ON 

LED 5 

 button 

LED 6 

 ON (RS) input 

LED 7 

 OFF input 

LED 8 

 RS output 

 
Feature 8: ERROR RESET 

 
The S.1 saves error conditions and indicates them with LED 8 or the flashing Error-LED. This feature 
allows fast and easy detection of even transient problems. 
To delete the error messages saved to the system, simply press the RESET button. 
 
The saved errors are also deleted when the TEACH process is started. 
 

Feature 9: ERRORS 

 
When the switch is this position, the LEDs indicate the nature of the problem: 
 
LED 1 

 blockage in ON direction 

LED 2 

 blockage in OFF direction 

LED 3 

 maximum force moving to ON 

LED 4 

 maximum force moving to OFF 