- 29 -
SETPOINT PROGRAMMING
From the weight display, press
to access the setpoint setting.
: to enter a menu/confirm the data entry.
: to modify the displayed figure or menu item.
: to select a new figure or modify the displayed menu item.
: to cancel and return to the previous menu.
-
(from 0 to full scale; default: 0): Setpoint; relay switching occurs when the weight exceed the
value set in this parameter. The type of switching is settable (see section OUTPUTS AND INPUTS
CONFIGURATION).
-
(from 0 to full scale; default: 0): Hysteresis, value to be subtracted from the setpoint to
obtain contact switching for decreasing weight. For example with a setpoint at 100 and hysteresis
at 10, the switching occurs at 90 for decreasing weight.
These values are set to zero if the calibration is changed significantly (see sections
THEORETICAL CALIBRATION and REAL CALIBRATION (WITH SAMPLE WEIGHTS)).
…
…