background image

LAUNCH                                                                                                                                                                Paint    Booth

 

 

 

                    Exhaust Duct                      Spraying/Baking Room                          Hot Wind Generator 

 
 
 
 
 
 
 
 
 
 
 
 

 

(Paint Baking ) 

 
 
 
 
 

Function Description of Switches and Meters on Electric Controller 

 
 
 
 
 

 

 

       

Power Supply            Ignition                Breakdown            Operation 
  Indication              Indication              Indication              Indication 

 
 

 

Thermograph                                    Timer 

   

                 

 
Ignition              Lighting                  Reset                      Key   

          Switch                Switch                  Switch                    Switch

 

 
 
 
 
 

 

 

PDF 

文件使用

 "pdfFactory Pro" 

试用版本创建

 

www.fineprint.com.cn

Summary of Contents for CCH-101

Page 1: ...ls on this manual for purposes or for all other questions relating to this manual Copyright Information Copyright 2000 by LAUNCH TECH CO LTD All rights reserved No part of this publication may be repr...

Page 2: ...praying paint clean the automobiles And remove the dangerous goods which are inflammable and exposable expect the gasoline in the gasoline tank from the automobiles l During spraying pass in and out o...

Page 3: ...ation l Function Description of Switches and Meters on Electric Controller l Operation Procedures of the paint booth l Operation Procedures of Burners l Cautions on using paint booth l Daily Maintenan...

Page 4: ...velocity within booth m s 0 25 0 35 0 25 0 35 0 25 0 35 0 25 0 35 0 3 0 5 Ventilation times times hr 265 352 265 299 332 Working temperature 60 80 60 80 60 80 60 80 60 80 Oil consumption kg set 6 8 9...

Page 5: ...ill maintain positive pressure all along to keep the dust from coming in Exhaust Duct Spraying Baking Room Hot wind generator Paint Spraying Paint Baking During baking use the automatically controlled...

Page 6: ...t Baking Function Description of Switches and Meters on Electric Controller Power Supply Ignition Breakdown Operation Indication Indication Indication Indication Thermograph Timer Ignition Lighting Re...

Page 7: ...h Setting Desired Value by Knobs Move the function switch with hand to the setting position turn the knobs and the value on the temperature indicator shows the real temperature inside the baking room...

Page 8: ...es the impellers of air blowers and oil pumps The impellers blow fresh air into combustion chambers and the gasoline is drawn inward through oil in pipe into oil pumps where the air and superfluous oi...

Page 9: ...them before spraying paint Daily Maintenance of Paint Booth l Use compressed air to clean the first filter net every 40 working hours l Clean the filter net at the nozzle of the oil in pipe of burner...

Page 10: ...there is no black smoke Motor in burner doesn t run 1 Time set on the time izndicator is up 2 Temperature set on the temperature indicator is up 3 Oil pump gets stuck 1 Reset the time 2 Rset the temp...