To avoid electric shock while using the probe, make
sure the insulated cable is perfect, and do not touch the metallic portions
of the probe head while it is connected with a high-voltage source.
7.3.3.2 Connection
For different applications, the connection methods may vary.
1. Power the Scopebox on: Power is provided to the Scopebox in
either of the following ways:
• Power adapter
: Insert one end of the power adapter into the
Power interface of the Scopebox, and the other end to the AC
outlet.
• Battery clamps cable
: Plug one end of the power adapter into
the Power interface of the Scopebox, and then clamp the other
two terminals to the vehicle's battery (Red to +, and Black to -)
respectively.
2. Connect the B-shaped terminal of the data cable to the Scopebox
Data I/O port, and the other end to the Data I/O port of the
diagnostic tool.
A. While testing sensors or actuators,
3. Connect the BNC connector of the BNC to 4mm test lead to the
CH1/CH2/CH3/CH4, and plug the black (GND) and red (SIGNAL)
4mm connectors into the Black (GND) and other color (SIGNAL)
banana sockets of the 6-way breakout leads respectively.
Black connector
to Black socket
Red connector
to the other color
socket
Connect to
any Channel
BNC to 4mm
test lead
Scopebox
6-way breakout lead
Fig. 7-22
4. Connect the black terminal and signal wire (its other end connected
to the red 4mm connector) of the 6-way breakout lead to the GND
and signal terminal of the vehicle sensor.
B. While testing Secondary-distributor ignition analysis/Secondary-
simultaneous ignition analysis,
3. Connect the BNC connector of the secondary ignition pick-up to
any channel of the Scopebox, and clamp the crocodile clips and
high-voltage clips onto the vehicle ground and high-voltage line
respectively.
The connection is as follows: